Supraacetabular Fossa (Pseudodefect of Acetabular Cartilage): Frequency at MR Arthrography and Comparison of Findings at MR Arthrography and Arthroscopy

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[High-Resolution MR Examination of the Scapholunate Ligament using a Microscopic Coil: Comparison with Direct MR Arthrography and Arthroscopy Findings].

PURPOSE OF THE STUDY Scapholunate dissociation is a clinically most frequently diagnosed form of carpal instability. The aim of this study was to compare high resolution MRI using a microscopic coil with direct MRI arthrography in patients with suspected scapholunate ligament lesions and compare the results with arthroscopy findings and Geissler's arthroscopy classification. MATERIAL AND METHOD...

متن کامل

Evaluation of the acetabular labrum by MR arthrography.

Since January 1993 we have carried out MR arthrography on 23 patients with clinical symptoms and signs of abnormality of the acetabular labrum. Most of the patients were young adults. Such symptoms are known precursors of osteoarthritis, and therefore early and accurate evaluation is required. We assessed the value of MR arthrography of the hip as a minimally-invasive diagnostic technique, in a...

متن کامل

Subscapularis tendon tears: detection and grading at MR arthrography.

PURPOSE To assess diagnostic accuracy in the detection and grading of subscapularis tendon lesions at magnetic resonance (MR) arthrography. MATERIALS AND METHODS MR arthrograms in 50 consecutive patients (29 with normal subscapularis tendons, 11 with a lesion in the cranial quarter, seven with a major tear but not complete detachment, three with complete detachment) with arthroscopic or surgi...

متن کامل

Morbidity of direct MR arthrography.

OBJECTIVE The purpose of this study was to determine the incidence and severity of arthrographic pain after intraarticular injection of a gadolinium mixture diluted in normal saline for direct MR arthrography. SUBJECTS AND METHODS From March 2009 until January 2010, 155 consecutive patients underwent direct MR arthrography; 20 patients were lost to follow-up. Patients were contacted by teleph...

متن کامل

MR and CT arthrography of the wrist.

The study of the wrist represents a major diagnostic challenge because of its complex anatomy and the small size of individual structures. Recent advances in imaging techniques have increased our diagnostic capabilities. However, 3T magnets, multichannel specific wrist coils, and new MRI sequences have not restricted the indications of arthrographic imaging techniques (CT arthrography and MR ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiology

سال: 2012

ISSN: 0033-8419,1527-1315

DOI: 10.1148/radiol.12111397