Supply Power Factor Improvement in Ozone Generator System Using Active Power Factor Correction Converter
نویسندگان
چکیده
منابع مشابه
Simulation of Active Power Factor Correction Using Boost Type Converter
With the vast development in the usage of Power electronic devices like Rectifiers (nonlinear loads) the current drawn from the line is distorted resulting in a High Total Harmonic Distortion (THD) and Low Power Factor (PF). Hence there is a continuous need for Power factor improvement and reduction of line current harmonics. The most popular topology for Active PFC is a boost converter as it d...
متن کاملModified Bi-directional AC/DC Power Converter with Power Factor Correction
Most existing power converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...
متن کاملImproved Parallel Boost Power Converter for Power Factor Correction
The main objective of the study is to analysis and design parallel boost power converter for power factor correction using an active filtering approach by implementing single-phase soft-switching technique with an active snubber circuit. Zero voltage transition to turn ON and zero current transition to turn OFF is implemented by the active snubber circuit for the main switches with no any furth...
متن کاملPower factor improvement using DCM Cuk converter with coupled inductor - Electric Power Applications, IEE Proceedings-
Most of the power factor regulator topologies in continuous conduction mode result in bulky magnetics, and in discontinuous conduction mode result in high harmonic content. To solve these problems a Cuk topology is presented in discontinuous conduction mode (DCM) with coupled inductors for power factor regulation, the unique feature exhibited by the converter that makes the converter better tha...
متن کاملImprovement In Performance Of Power Factor Correction Converters For Distributed Power System
In present situation, the power control of a DC load can be achieved via an AC-DC converter consisting of a rectifier bridge and a switching element (operating by sPWM technique). The use of such a converter causes a lot of high harmonics at the AC side, which reduce the power factor and distort the grid voltage. Using passive filter in the converter input to avoid the high harmonics consequenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Power Electronics and Drive Systems (IJPEDS)
سال: 2015
ISSN: 2088-8694,2088-8694
DOI: 10.11591/ijpeds.v6.i2.pp326-336