منابع مشابه
Modeling High-Temperature Superconductivity: Correspondence at Bay?∗
How does a predecessor theory relate to its successor? According to Heinz Post’s General Correspondence Principle, the successor theory has to account for the empirical success of its predecessor. After a critical discussion of this principle, I outline and discuss various kinds of correspondence relations that hold between successive scientific theories. I then look in some detail at a case st...
متن کاملSolar coronal observations at high frequencies
The Solar Eclipse Coronal Imaging System (SECIS) is a simple and extremely fast, high-resolution imaging instrument designed for studies of the solar corona. Light from the corona (during, for example, a total solar eclipse) is reflected off a heliostat and passes via a Schmidt-Cassegrain telescope and beam splitter to two CCD cameras capable of imaging at 60 frames a second. The cameras are at...
متن کاملPolarization Properties of AGN at High Frequencies
I discuss variability of polarization in the core region of parsec scale radio jets and connections between 7 mm polarization in the VLBI core and polarization at shorter wavelengths from the whole source for a sample of AGN with highly relativistic jets known as blazars. The sources show pronounced diversity in polarization behavior that is not clearly understood. I discuss possible reasons fo...
متن کاملProton assisted recoupling at high spinning frequencies.
We demonstrate the successful application of (13)C-(13)C proton assisted recoupling (PAR) on [U-(13)C,(15)N] N-f-MLF-OH and [U-(13)C,(15)N] protein GB1 at high magic angle spinning (MAS) frequencies (omega(r)/2pi = 65 kHz). Specifically, by combining PAR mixing with low power heteronuclear decoupling (omega(1H)/2pi approximately 16 kHz) and high spinning frequencies, we obtain high resolution 2...
متن کاملEqual-loudness Contours at High Frequencies
Interfrequency loudness matches were obtained for 12 pairs of frequencies from 1 to 16 kHz over a range of sensation levels (SL) from 4-to-100 dB. At 10 kHz and below, a linear matching function with a slope of 1.0 provides a good account of the data. In contrast, loudness-matching functions at higher frequencies are curvilinear in shape. Moreover, the regional slope values are both level and f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nature
سال: 1931
ISSN: 0028-0836,1476-4687
DOI: 10.1038/1281004d0