Suction pumping method through 41Ar attenuation tanks for reduction of 41Ar dose rate.
نویسندگان
چکیده
منابع مشابه
Applicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملsemi-analytical solution for static and forced vibration problems of laminated beams through smooth fundamental functions method
در این پایان نامه روش جدیدی مبتنی بر روش حل معادلات دیفرانسیل پارهای بر اساس روش توابع پایه برای حل مسایل ارتعاش اجباری واستاتیک تیرها و صفحات لایه ای ارایه شده است که می توان تفاوت این روش با روش های متداول توابع پایه را در استفاده از توابع هموار در ارضاء معادلات حاکم و شرایط مرزی دانست. در روش ارایه شده در این پایاننامه از معادله تعادل به عنوان معادله حاکم بر رفتار سیستم استفاده شده است که مو...
15 صفحه اولThyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملapplicator attenuation effect on dose calculations of esophageal high-dose rate brachytherapy using edr2 film
introduction interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. the effect of applicator attenuation is not considered in dose calculation method released by aapm-tg43. in this study, the effect of high-dose rate (hdr) brachytherapy esophageal applicator on dose distribution was surveyed in hdr brachytherapy. materials and methods a cylindrical pmma phan...
متن کاملOptimal dose reduction algorithm using an attenuation-based tube current modulation method for cone-beam CT imaging
To reduce the radiation dose given to patients, a tube current modulation (TCM) method has been widely used in diagnostic CT systems. However, the TCM method has not yet been applied to a kV-CBCT system on a LINAC machine. The purpose of this study is to investigate if a TCM method would be desirable in a kV-CBCT system for image-guided radiation therapy (IGRT) or not. We have developed an atte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Atomic Energy Society of Japan / Atomic Energy Society of Japan
سال: 1989
ISSN: 0004-7120
DOI: 10.3327/jaesj.31.837