Successful Retrieval of a Stuck Guidewire by Guiding Catheter Lock Technique in Renal Artery Stenting
نویسندگان
چکیده
منابع مشابه
Successful Retrieval of an Entrapped Rotablator Burr by Using a Guideliner Guiding Catheter and a Snare.
Although burr entrapment is a rare complication of rotablation, it is extremely difficult to retrieve a stuck entrapped burr without surgical intervention. There are several techniques typically employed to retrieve an entrapped burr, using bailout endovascular approaches. Herein we have presented a new retrieval method involving a Guideliner child-in-mother catheter combined with a snare, whic...
متن کاملSuccessful Retrieval of a Dismembered Central Venous Catheter Stuck to the Right Pulmonary Artery Using a Stepwise Approach
Recent advances in anticancer chemotherapy have resulted in an increase in the number of patients requiring a central venous port catheter, and the incidence of catheter pinch-off syndrome has been increasing. Catheter pinch-off syndrome is a rare and unusual complication. It is difficult to retrieve dislodged catheters from the pulmonary artery, especially if the catheter is stuck to the perip...
متن کاملthe role of choice-lock catheter and trocar technique in percutaneous ablation of symptomatic renal cysts
conclusions percutaneous ethanol sclerotheraphy in simple cysts is a safe, cost-effective and minimally invasive method. we consider that this technique may be an alternative solution in the percutaneous cyst treatment. results fifty-seven cysts had complete regression, while 31 cysts regressed partially. after the procedure, pain was relieved in 44 (82%) patients and the pain alleviated in fou...
متن کاملModification of the No-Touch Technique during Renal Artery Stenting
Renal artery stenting has been established as the primary form of renal artery stenosis revascularization procedure. The no-touch technique is proposed in order to avoid renal artery injury and atheroembolism during renal artery stenting. We describe a modification of the no-touch technique by using an over-the-wire (OTW) balloon or a Quickcross 0.014'' catheter with a 0.014'' coronary wire ins...
متن کاملFracture of a guiding catheter in a tortuous iliac artery and its retrieval by a larger sheath.
Intravascular fracture of catheters, especially guiding catheters, is uncommon. We present an unusual case in which a guide twisted and broke in a tortuous iliac artery during manipulation of the guiding catheter with a 0.014 inch wire firmly trapped inside and was retrieved by a larger sheath.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: EJVES Vascular Forum
سال: 2020
ISSN: 2666-688X
DOI: 10.1016/j.ejvsvf.2020.10.004