Successful implantation of a left ventricular lead in an anomalous coronary sinus
نویسندگان
چکیده
منابع مشابه
successful implantation of coronary sinus lead after balloon angioplasty of a coronary vein stenosis
a 55-year-old man referred for cardiac resynchronization therapy (crt) due to severe heart failure. a severe stenosis in the coronary sinus vein after the posterior branch disallowed the insertion of the lead. nevertheless, the stenosis was dilated and the left ventricle (lv) lead was implanted in the lateral marginal branch.
متن کاملSuccessful implantation of the left ventricular pacing lead in the posterolateral cardiac vein after coronary sinus dissection during biventricular pacing.
Successful Implantation of the Left Ventricular Pacing Lead in the Postero-Lateral Cardiac Vein After Coronary Sinus Dissection During Biventricular Pacing SkevoS SideriS, StefanoS archontakiS, konStantinoS GatzouliS, PolychroniS dilaveriS, ioanniS vlaSeroS, ioanniS kallikazaroS, chriStodouloS StefanadiS State Cardiology Division, First University Department of Cardiology, Hippokration General ...
متن کاملCoronary sinus dissection during left ventricular pacing electrode implantation.
Coronary sinus (CS) dissection during biventricular pacing electrode implantation is a complication that rarely develops. A 71-year-old female with recurrent ventricular tachycardia, heart decompensation, and poor left ventricular function because of dilated cardiomyopathy was admitted for the implantation of a cardioverter-defibrillator for biventricular pacing. During the operation, we experi...
متن کاملCoronary vein balloon angioplasty for left ventricular pacemaker lead implantation.
OBJECTIVES Retrospective analysis of five cases of coronary vein balloon angioplasty performed to allow insertion of left ventricular pacing leads. BACKGROUND Coronary vein stenoses or an insufficient vessel caliber can preclude transvenous placement of coronary vein leads. METHODS We compared our total patient population (n = 218), in whom we implanted coronary vein leads, to those five pa...
متن کاملMagnetically guided left ventricular lead implantation based on a virtual three-dimensional reconstructed image of the coronary sinus
AIMS Left ventricular (LV) lead implantation is feasible using remote magnetic navigation of a guidewire (Stereotaxis, St Louis, MO, USA). A novel software that performs a three-dimensional (3D) reconstruction of vessels based on two or more angiographic views has been developed recently (CardiOp-B system, Paeion Inc., Haifa, Israel). The objective of this paper is to evaluate: (i) the performa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Arrhythmia
سال: 2021
ISSN: 1880-4276,1883-2148
DOI: 10.1002/joa3.12553