Sub-100 attoseconds stability optics-to-microwave synchronization
نویسندگان
چکیده
منابع مشابه
Beyond Attoseconds
We briefly review the pilot ideas on the generation of electromagnetic (EM)-pulses much shorter than already available sub-femtosecond pulses, and outline inroads and venues into the physics of pulses much shorter than an attosecond (10 seconds), in particular the so called zeptosecond (10 seconds) and yoctosecond (10 seconds) pulses that may allow one to operate on QED and nuclear, as well as ...
متن کاملBalanced optical-microwave phase detector for sub-femtosecond optical-RF synchronization.
We demonstrate that balanced optical-microwave phase detectors (BOMPD) are capable of optical-RF synchronization with sub-femtosecond residual timing jitter for large-scale timing distribution systems. RF-to-optical synchronization is achieved with a long-term stability of < 1 fs RMS and < 7 fs pk-pk drift for over 10 hours and short-term stability of < 2 fs RMS jitter integrated from 1 Hz to 2...
متن کاملTransformation Optics and Applications in Microwave Frequencies
Modern electrical and communication technologies benefit from classical electrodynamics and electric circuits, both of which are based on the Maxwell’s equations. Using the property of metric invariance in Maxwell’s Equations, transformation optics has been proposed and achieves a rapid progress in the past decade. Transformation optics is a method for the conceptual design of complex electroma...
متن کاملSolid-state optical refrigeration to sub-100 Kelvin regime
Since the first demonstration of net cooling twenty years ago, optical refrigeration of solids has progressed to outperform all other solid-state cooling processes. It has become the first and only solid-state refrigerator capable of reaching cryogenic temperatures, and now the first solid-state cooling below 100 K. Such substantial progress required a multi-disciplinary approach of pump laser ...
متن کاملSub-Airy Confocal Adaptive Optics Scanning Ophthalmoscopy
Purpose To demonstrate the viability of improving transverse image resolution in reflectance scanning adaptive optics ophthalmoscopy using sub-Airy disk confocal detection. Methods The foveal cone mosaic was imaged in five human subjects free of known eye disease using two custom adaptive optics scanning light ophthalmoscopes (AOSLOs) in reflectance with 7.75 and 4.30 mm pupil diameters. Conf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Applied Physics Letters
سال: 2010
ISSN: 0003-6951,1077-3118
DOI: 10.1063/1.3431299