SU-E-T-497: Initial Characterization of a Novel 2D Computed Radiography (CR) Dosimeter for SBRT
نویسندگان
چکیده
منابع مشابه
SU-E-T-404: A Prototype Program for Analyzing 4D Image Guidance Shifts for Lung SBRT.
PURPOSE A prototype in-house program was developed to assist deriving image guidance shifts clinically using our 4DCT method for lung SBRT. METHODS Our in-house prototype program was implemented in MATLAB. The 4D DICOM CT dataset of interest is imported by the program from AW and subsequently accepts input from the user regarding the desired relative IGRT shifts. The DICOM header information ...
متن کاملSU-E-T-497: Study of Restricted Mass Stopping Power Ratio in Small Electron Tube Fields.
PURPOSE Electron tubes with small radii are useful to treat narrow regions which cannot accommodate normal electron applicators. In small electron fields, it is not trivial to estimate restricted mass stopping power ratio (MSR), which is needed to evaluate dose from ion chamber measurement. We studied MSRs in small electron tube fields using the Monte Carlo simulation. METHODS Electron tubes ...
متن کاملSU-E-T-312: Optically Stimulated Luminescent Dosimeter Performance in High Dose Rate Brachytherapy.
PURPOSE To investigate the use of optically stimulated luminescent dosimeters (OSLDs) for high dose rate (HDR) Ir-192 brachytherapy. While common in megavoltage radiotherapy applications, the performance of OSLDs using kilovoltage energies, high dose gradient and high dose rate regions ubiquitous to HDR has not been demonstrated. METHODS Commercially available nanoDotTM (Landauer, Glenwood, I...
متن کاملA Novel Neutron Dosimeter
Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...
متن کاملStomach and duodenum: radiographic magnification using computed radiography (CR).
We performed direct radiographic magnification (X3) using a 0.1-mm microfocal tube and computed radiography (CR) in air-barium double-contrast studies of the stomach and duodenum. To eliminate blurring of the image due to motion, we used the maximum kilovolt peak rate possible (102 kVp), the maximum milliampere second rate possible (64 mAs), the shortest possible exposure time (0.1 second), and...