Stylet for reinforced laryngeal mask airway
نویسندگان
چکیده
منابع مشابه
The reinforced laryngeal mask airway for dento-alveolar surgery.
We have evaluated the reinforced laryngeal mask airway (LMA) for use during dento-alveolar surgery in 100 ASA I and II day-case patients allocated randomly to receive either a nasotracheal tube or reinforced LMA. We recorded ease of airway insertion, airway complications, quality of recovery and replies to a 24-h postoperative questionnaire. In addition, a fibreoptic assessment was made of lary...
متن کاملSubmental Intubation with Reinforced Tube for Intubating Laryngeal Mask Airway
Submental endotracheal intubation is a simple and secure alternative to either nasoendotracheal intubation or a tracheostomy in the airway management of maxillofacial trauma. However, a submental endotracheal intubation is quite difficult to manage if adverse events such as a tube obstruction, accidental extubation, or a leaking cuff with the endotracheal tube in the submental route occur, whic...
متن کاملKTP laser-resistant properties of the reinforced laryngeal mask airway.
We have assessed, in vitro, the effect of KTP laser strike on the reinforced laryngeal mask airway (RLMA) under a variety of conditions. At power densities normally encountered in clinical practice, using a divergent KTP laser beam, the RLMA could not be penetrated and did not ignite with laser strike. The RLMA was penetrated at a high power density of 6.94 W mm-2 after 45-60 s. A flame appeare...
متن کاملThe Rusch Flexi-Slip stylet for ProSeal laryngeal mask airway insertion.
CAN J ANESTH 55: 10 www.cja-jca.org October, 2008 ing drugs (NMBDs). Anesthesia was maintained with desflurane in oxygen, and her trachea was extubated at the end of the procedure without incident. Save for a prolonged duration of analgesia lasting approximately 30 hr, telephone follow-up revealed that the patient’s recovery was unremarkable with eventual complete resolution. Traditionally, due...
متن کاملUse of Shikani Flexible Seeing Stylet for intubation via the Intubating Laryngeal Mask Airway.
detailed evaluation; however it presents clear advantages for monitoring SjO2 during CEA. Further refinements may improve this technique, including use of a guide wire for introducing the catheter into the internal jugular vein. In addition, this method should be compared with the conventional technique of monitoring SjO2 during CEA in terms of 1) accuracy and continuity of measurements, 2) tim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Anaesthesia
سال: 1993
ISSN: 0003-2409,1365-2044
DOI: 10.1111/j.1365-2044.1993.tb07137.x