STUDY ON SEISMIC PERFORMANCE OF SELF-CENTERING STEEL FRAME WITH WEDGE DEVICE
نویسندگان
چکیده
منابع مشابه
Performance Evaluation of Curved-TADAS Damper on Seismic Response of Moment Resisting Steel Frame
In this study, the performance of triangular added damping and stiffness (TADAS) dampers combined with curved dampers (Curved-TADAS damper) is evaluated in moment resisting steel frame (MRSF). These dampers are passive and install in the beam-column connection region. Variable parameters of this study involve the width of curved damper (50, 75 and 100 mm), the thickness of TADAS damper (5 and 1...
متن کاملEffect of column-foundation connection stiffness on seismic performance of rocking steel braced frame
Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...
متن کاملThe Effect of Frame Geometry on the Seismic Response of Self-Centering Concentrically- Braced Frames
Conventional concentrically-braced frame (CBF) systems have limited drift capacity before brace buckling and related damage leads to deterioration in strength and stiffness. Self-centering concentrically-braced frame (SC-CBF) systems have been developed to increase drift capacity prior to initiation of damage and minimize residual drift. SC-CBFs differ from conventional CBFs in that the SC-CBF ...
متن کاملSeismic Response of Steel Framed Hospital Buildings with Self-Centering Systems (2004-2005)
This paper introduces the concepts of Elasto-Plastic Systems (EPS) and Self-Centering Systems (SCS) for the seismic design of steel-framed hospital buildings. Redesign of the MCEER West Coast Demonstration Hospital with SCS is conducted using this approach. An ensemble of 25 simulated MCEER Ground Motions having a probability of exceedence of 5% in 50 years in Northridge, California is used as ...
متن کاملSeismic Response of a Platform-Frame System with Steel Columns
Timber platform-frame shear walls are characterized by high ductility and diffuse energy dissipation but limited in-plane shear resistance. A novel lightweight constructive system composed of steel columns braced with oriented strand board (OSB) panels was conceived and tested. Preliminary laboratory tests were performed to study the OSB-to-column connections with self-drilling screws. Then, th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 2015
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.80.1941