Study on Insulator Flashover Voltage Gradient Correction Considering Soluble Pollution Constituents
نویسندگان
چکیده
منابع مشابه
Study on Insulator Flashover Voltage Gradient Correction Considering Soluble Pollution Constituents
Dongdong Zhang 1, Zhijin Zhang 1,*, Xingliang Jiang 1, Zhongyi Yang 1, Jiayao Zhao 1 and Yongfu Li 2 1 State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing 400044, China; [email protected] (D.Z.); [email protected] (X.J.); [email protected] (Z.Y.); [email protected] (J.Z.) 2 State Grid Chongqing Electr...
متن کاملAnalysis of Flashover Voltages of Disc Type Insulator under Artificial Pollution Condition (TECHNICAL NOTE)
Through this paper work we have analyzed the effect of different contaminants on the flashover by creating artificial pollution condition, considering the natural condition where more than one salt as contaminant deposits on the surface of insulator at a time, under the wet condition that cause flow of highly leakage current, that leads to flashover. We choses the mixture of different salts, so...
متن کاملInvestigation of pollution flashover on high voltage insulators using artificial neural network
0957-4174/$ see front matter Crown Copyright 2 doi:10.1016/j.eswa.2008.11.008 * Corresponding author. Tel.: +90 424 2370000/523 E-mail addresses: [email protected] (M.T. Ge (M. Cebeci). High voltage insulators form an essential part of the high voltage electric power transmission systems. Any failure in the satisfactory performance of high voltage insulators will result in considerable lo...
متن کاملElectrical Circuit Flashover Model of Polluted Insulators under AC Voltage Based on the Arc Root Voltage Gradient Criterion
In order to study the flashover mechanism of polluted insulators under AC voltage, a new arc propagation criterion which is based on an arc root voltage gradient is proposed. This criterion can explain the variation of the arc root voltage gradient in the arc propagation process. Based on this criterion, a new distributed parameter electrical circuit flashover model of polluted insulators is pr...
متن کاملModel for Predicting DC Flashover Voltage of Pre-Contaminated and Ice-Covered Long Insulator Strings
In the current study, a multi-arc predicting model for DC critical flashover voltage of iced and pre-contaminated long insulator strings under low atmospheric pressure is developed. The model is composed of a series of different polarity surface arcs, icicle-icicle air gap arcs, and residual layer resistance. The calculation method of the residual resistance of the ice layer under DC multi-arc ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2016
ISSN: 1996-1073
DOI: 10.3390/en9110954