Study on Dual-Frequency Imaging of Capacitively Coupled Electrical Impedance Tomography: Frequency Optimization

نویسندگان

چکیده

In this work, a new dual-frequency imaging framework of capacitively coupled electrical impedance tomography (CCEIT) is presented. Unlike conventional single-frequency and recently emerged multi-frequency imaging, the adopts two different working frequencies to obtain real part imaginary impedance, respectively. With image reconstructed at frequencies, further introduces fusion fused image. To achieve optimal selection data collection in wide frequency range carried out with 12-electrode CCEIT sensor, an analyzer, computer measurements. The then analyzed depth other aspects, including sensitivity distribution quality are also investigated. Research results show that low recommended for part, while relatively high part. Within investigated 200 kHz - 20 MHz, optimized respectively under setups. Results verification experiment proposed effective. Compared CCEIT, has much better performance.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On a Calderón Problem in Frequency Differential Electrical Impedance Tomography

Recent research in electrical impedance tomography produce images of biological tissue from frequency differential boundary voltages and corresponding currents. Physically one is to recover the electrical conductivity σ and permittivity ε from the frequency differential boundary data. Let γ = σ+iωε denote the complex admittivity, Λγ be the corresponding Dirichlet-to-Neumann map, and dΛγ dω ∣∣∣ ...

متن کامل

Design of Voltage Measuring Circuits in Electrical Impedance Tomography Based on Dual Frequency Phase-Sensitive Demodulator

In this paper, a dual frequency phase sensitive demodulation (PSD) technique is suggested to measure electrode voltages in electrical impedance tomography. The simulation results obtained by the dual frequency PSD are compared with the single frequency PSD in terms of accuracy on a simple phantom.

متن کامل

Optimizing the Measurement Frequency in Electrical Impedance Tomography

In electrical impedance tomography (EIT), a small alternating current is injected into the patient and the resulting voltages are measured at the body surface. From this, images are reconstructed that can be used for ventilation and cardiac monitoring. In modern EIT systems and in prototypes, the frequency of the injected current can be varied in a range between typically 50 kHz and 250 kHz. In...

متن کامل

Frequency-Division Multiplexing for Electrical Impedance Tomography in Biomedical Applications

Electrical impedance tomography (EIT) produces an image of the electrical impedance distribution of tissues in the body, using electrodes that are placed on the periphery of the imaged area. These electrodes inject currents and measure voltages and from these data, the impedance can be computed. Traditional EIT systems usually inject current patterns in a serial manner which means that the impe...

متن کامل

A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System

A highly versatile Electrical Impedance Tomography (EIT) system, nicknamed the ScouseTom, has been developed. The system allows control over current amplitude, frequency, number of electrodes, injection protocol and data processing. Current is injected using a Keithley 6221 current source, and voltages are recorded with a 24-bit EEG system with minimum bandwidth of 3.2 kHz. Custom PCBs interfac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Instrumentation and Measurement

سال: 2022

ISSN: ['1557-9662', '0018-9456']

DOI: https://doi.org/10.1109/tim.2022.3187713