Study on Control of Horizontal Deflection and Storey Drift in Multi-Storey Buildings due to Lateral Loads by Changing Column Section
نویسندگان
چکیده
منابع مشابه
On-site greywater treatment and reuse in multi-storey buildings.
The paper presents a study of a pilot plant treating light greywater for seven flats. The pilot plant combines biological treatment (RBC) with physicochemical treatment (sand filtration and disinfection). The pilot plant produced effluent of excellent quality, meeting the urban reuse quality regulations, and was very efficient in TSS turbidity and BOD removal: 82%, 98% and 96%, respectively. CO...
متن کاملAtrium-assisted Natural Ventilation of Multi-storey Buildings
Buoyancy-driven displacement natural ventilation in a simple multi-storey building structure is investigated. The storeys are connected to a common atrium and top-down-chimneys, and the internal heat gains of the storeys are represented by localised point heat sources on each floor. The heat sources generate thermal plumes which entrain the surrounding air and transport warm air upwards. Simple...
متن کاملInfluence of Masonry Infills Walls on the Seismic Behaviour of Multi-storey Waffle Slabs Rc Buildings
In this work, we analyze the influence of masonry infill walls on the seismic performance of waffle slabs reinforced concrete (RC) framed structures. We analyze buildings of three, five and eight storeys, which are representative for a big number of housings in Barcelona, Spain. Capacity spectra have been obtained by performing pushover analyses and we have used a simplified procedure to obtain...
متن کاملNew Applications of Line of Balance on Scheduling of Multi-storey Buildings
New practical applications of the Line of Balance technique are presented, introducing simple and transparent tools for initial planning, short term scheduling and production control on multi-storey building construction sites. These developments were being conducted along an investigation on some construction sites on Brazil. The planning methodology is discussed including preplanning details ...
متن کاملIs it necessary to measure impact sound insulation from 20 Hz in lightweight multi-storey buildings?
It has previously been notified that residents living in lightweight multi-storey family houses do not experience the impact sound insulation to be as good as in an equivalent concrete building despite the same single number rating, L’n,w+CI,50-2500. From a comprehensive national research program in Sweden, it was recently indicated that the lowest frequencies, 20-50 Hz, are crucial when it com...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Science and Technology
سال: 2016
ISSN: 0974-5645,0974-6846
DOI: 10.17485/ijst/2016/v9i30/99204