Study on Cone Beam X-Ray Scattering Correction Applied to Bone Densitometer
نویسندگان
چکیده
منابع مشابه
X-Ray Scatter Correction on Soft Tissue Images for Portable Cone Beam CT.
Soft tissue images from portable cone beam computed tomography (CBCT) scanners can be used for diagnosis and detection of tumor, cancer, intracerebral hemorrhage, and so forth. Due to large field of view, X-ray scattering which is the main cause of artifacts degrades image quality, such as cupping artifacts, CT number inaccuracy, and low contrast, especially on soft tissue images. In this work,...
متن کاملRecent Advances in X-ray Cone-beam Computed Laminography.
X-ray computed tomography is an established volume imaging technique used routinely in medical diagnosis, industrial non-destructive testing, and a wide range of scientific fields. Traditionally, computed tomography uses scanning geometries with a single axis of rotation together with reconstruction algorithms specifically designed for this setup. Recently there has however been increasing inte...
متن کاملAutomatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions.
Intraoperative imaging offers a means to account for morphological changes occurring during the procedure and resolve geometric uncertainties via integration with a surgical navigation system. Such integration requires registration of the image and world reference frames, conventionally a time consuming, error-prone manual process. This work presents a method of automatic image-to-world registr...
متن کاملAn Improved Cone-beam Filtered Backprojection Reconstruction Algorithm Based on X-ray Angular Correction and Multiresolution Analysis
With the extensive application of industrial computed tomography in the field of nondestructive testing, how to improve the quality of the reconstructed image is receiving more and more concern. It is well known that in the existing cone-beam filtered backprojection reconstruction algorithms the cone angle is controlled within a narrow range. The reason of this limitation is the incompleteness ...
متن کاملScan Mode Performance of Dual Energy X-ray Absorptiometry Bone Densitometer
Objective: A commercially available dual energy X-ray absorptiometry scanner normally provides more than 1 scan mode. The differences between scan modes affect scan time, received radiation dose, and quality of the scan image. A phantom study was performed to evaluate the performance of different scan modes for anteriorposterior spine scan. Patients and Methods: To measure the entrance skin exp...