Study on Coaxial Double Pipe Air Jets at Different Temperatures.
نویسندگان
چکیده
منابع مشابه
Acoustic Simulation of Coaxial Hot Air Jets Using Cold Helium–Air Mixture Jets
This work examines the ability of small-scale helium–air mixture coaxial jets to simulate the acoustics of largescale hot air jets representing the exhaust of separate-flow turbofan engines. Experiments employed a one-eighthscale model of a separate-flow nozzle used in hot tests at NASA John H. Glenn Research Center. Comparisons were conducted for two set points using the following methods: mat...
متن کاملTolerability of Nasal Delivery of Humidified and Warmed Air at Different Temperatures: A Randomised Double-Blind Pilot Study
OBJECTIVES Delivery of warmed, humidified air via nasal high flow therapy could potentially reduce replication of temperature-sensitive viruses in the upper respiratory tract. This study investigates whether nasal high flow therapy is well tolerated by healthy adults at 37°C and 41°C. METHODS In this randomised, double-blind, controlled crossover pilot trial, nasal high flow therapy was used ...
متن کاملAcoustic Simulation of Hot Coaxial Jets Using Cold Helium-air Mixture Jets
This work examines the ability of small-scale, helium-air-mixture, coaxial jets to capture the acoustics of large-scale hot jets representing the exhaust of separate-flow turbofan engines. Experiments at University of California, Irvine (UCI) employed a one-eighth-scale model of a separate-flow nozzle being used at the Nozzle Acoustic Test Rig (NATR) of NASA Glenn Research Center. Comparisons w...
متن کاملTheoretical Thermodynamic Study of Solvent Effects on Serine and Threonine Amino Acids at Different Temperatures
The thermodynamic functions such as enthalpy (H), Gibbs free energy (G) and entropy (S) of Serineand Threonine amino acids were theoretically studied at different condition (solvents andtemperatures) by using Gussian o3, software. First, the structural optimization of isolated Serine andThreonine were done in the gas phase by using the Hartree-Fock (HF) level of theory with 3-21G, 6-31G and 6-3...
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B
سال: 1997
ISSN: 0387-5016,1884-8346
DOI: 10.1299/kikaib.63.637