Study of the Lightning Overvoltage Protection Effectiveness of High Voltage Mixed Overhead Cable Power Lines

نویسندگان

چکیده

In this paper, the effectiveness of lightning overvoltage protection cables in high voltage overhead cable lines has been analyzed. Because level, are protected by surge arresters and metallic sheath earthing. However, practice, quite a lot cases electricity-evoked damage to outer sheaths observed, proving that used is insufficient. As result, exposed environmental factors, especially moisture penetration, which contributes degradation. To explain causes situation, simulation studies were carried out determine relevant factors affecting level expected overvoltages. The circuit-field model line EMTP-ATP, COMSOL MATLAB software was for determining overvoltages on main insulation protective sheath. reveal efficiency ensured regardless strike location crest value its current. obtained results confirm no matter applied protection, may be with higher values than those insulation. Although analysis performed 110 kV lines, conclusions general also applicable power rated voltages.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lightning Protection of Overhead Power Distribution Lines

Distribution lines are often located in areas with high ground flash densities, being therefore subject to lightning-caused power interruptions. This paper presents an overview of the various types of lightning overvoltages that can arise on overhead power distribution networks, as well as typical voltage waveforms. The effectivenesses of the most important methods for mitigating such overvolta...

متن کامل

A Novel Method to Reconstruct Overhead High-Voltage Power Lines Using Cable Inspection Robot LiDAR Data

Overhead high-voltage power lines are key components of power transmission and their monitoring has a very significant influence on security and reliability of power system. Advanced laser scanning techniques have been widely used to capture three-dimensional (3D) point clouds of power system scenes. Nevertheless, power line corridors are found in increasingly complex environments (e.g., mounta...

متن کامل

Performance of Medium Voltage Overhead Distribution Lines Against Lightning Discharges

The lightning discharges are one of the main causes of interruptions of medium voltage overhead distribution lines, being the reason of great concern for the utility companies. Its destructive effects frequently extends to equipments and connected installations, with the possibility to cause personal injuries and material damages, beyond economic losses, due to out of income and the possibility...

متن کامل

Evaluation of Arrester’s Protection Levels during Lightning Strikes to Overhead Medium Voltage Lines

This paper present an evaluation of overvoltages in low-voltage LV installation in buildings in cases of direct lightning strikes to overhead medium voltage lines. The study considered typical power systems with lowand medium voltage surge arresters. The calculation have been performed using the EMPTATP

متن کامل

Adult cancers near high-voltage overhead power lines.

BACKGROUND Extremely low-frequency magnetic fields are designated as possibly carcinogenic in humans, based on an epidemiologic association with childhood leukemia. Evidence for associations with adult cancers is weaker and inconsistent. METHODS We conducted a case-control study to investigate risks of adult cancers in relation to distance and extremely low-frequency magnetic fields from high...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2021

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en14082329