Study of Short Circuit and Inrush Current Impact on the Current-Limiting Reactor Operation in an Industrial Grid
نویسندگان
چکیده
Current-limiting reactors are widely used in industrial electrical grids to reduce the current amplitude equipment and stabilize voltage on busbar during short circuits. Their application is distinguished by high technical economic efficiency. However, mechanical damage has been observed within extensive with many induction motors internal synchronous generators. The article analyses a case study of reactor true grid circuit. An analysis damaged reactor’s previous operation had shown that there was weakening fastenings design, caused repeated starting currents A transients circuits carried out Matlab/Simulink software. simulation results showed could be critical peak an unfavourable combination configuration circuit location. prove that, for networks containing powerful generators, standardized procedure selecting current-limiting should additionally consider such factors as localization grid, effect equipment-starting possible configurations.
منابع مشابه
the u.s. policy in central asia and its impact on the colored revolutions in the region (the case study of tulip revolution in kyrgyzstan)
چکیده ندارد.
15 صفحه اولan investigation of the impact of self monitoring on langauge teachers motivational practice and its effect on learners motivation
the central purpose of this study was to conduct a case study about the role of self monitoring in teacher’s use of motivational strategies. furthermore it focused on how these strategies affected students’ motivational behavior. although many studies have been done to investigate teachers’ motivational strategies use (cheng & d?rnyei, 2007; d?rnyei & csizer, 1998; green, 2001, guilloteaux & d?...
the impact of e-readiness on ec success in public sector in iran the impact of e-readiness on ec success in public sector in iran
acknowledge the importance of e-commerce to their countries and to survival of their businesses and in creating and encouraging an atmosphere for the wide adoption and success of e-commerce in the long term. the investment for implementing e-commerce in the public sector is one of the areas which is focused in government‘s action plan for cross-disciplinary it development and e-readiness in go...
Decreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points
Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...
متن کاملMitigation Transformer Inrush Current Using Modified Transient Current Limiter
This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2023
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en16020811