Study of Induced Astigmatism After Cataract Surgery by Phacoalternative
نویسندگان
چکیده
The objective is to study the astigmatism induced after phacoalternative surgery in order improve quality of surgery. This was a prospective and descriptive cross-sectional carried out at Donka University Hospital Conakry from july 2021 january 2022, i.e. duration 7 months, on 100 operated eyes. It involved eyes, by with an upper limbal incision least 6 mm implantation lens bag. Automatic refraction performed pre-operatively post-operatively 45ᵉ day. mean age 62 years. Visual acuity reduced light perception 58% cases preoperatively. implant power biometry 19±2.38 Dioptres (D); 50% patients received calculated implant. Corneal oedema most frequent early complication. Regarding functional outcome, 82% eyes had uncorrected visual greater than 3/10 D45 92% correction. 95% preoperative less 2D 57% according rule. average postoperative 3.15D against In conclusion, linear superior induces rule 3.15 dioptres average.
منابع مشابه
Astigmatism following cataract surgery.
The changes in corneal curvature were determined at regular intervals over a one-year period following intracapsular cataract extraction by microsurgical techniques. During the first postoperative month photokeratometric measurements showed rapid changes in astigmatism associated with large changes in the direction of the axis. Thereafter astigmatism against-the-rule predominated. Data from the...
متن کاملAstigmatism in cataract surgery.
We report on our investigation into astigmatism in 40 eyes following a corneal cataract incision closed with a continuous 10/0 nylon monofilament suture (Ethilon). Immediately after surgery there was astigmatism caused by the nylon suture (suture-induced astigmatism), its severity depending on the tightness of the suture. It ranged from 1 to 10-5 dioptres, the mean value 4-09 dioptres with a st...
متن کاملAstigmatism in cataract surgery MAURICE
We report on our investigation into astigmatism in 40 eyes following a corneal cataract incision closed with a continuous 10/0 nylon monofilament suture (Ethilon). Immediately after surgery there was astigmatism caused by the nylon suture (suture-induced astigmatism), its severity depending on the tightness of the suture. It ranged from 1 to 10 5 dioptres, the mean value 4 09 dioptres with a st...
متن کاملAnalysis of cataract surgery induced astigmatism: Two polar methods comparison
PURPOSE Surgically induced astigmatism (SIA) caused by the incision after cataract surgery may be calculated to improve IOL toric power calculation and achieve better visual outcome. SIA could be determined as the difference between preoperative and postoperative keratometry expressed in polar values using different equations. The objective of this study is to compare the SIA calculated with tw...
متن کاملSurgically induced astigmatism of small incision cataract surgery.
I would like to congratulate the authors who contributed the article “Comparison of astigmatism following manual small incision cataract surgery: superior versus temporal approach,” which was published in Nepal J Ophthalmol 2012; 4(7):54-58. As one who follows new discussions in the field of cataract and refractive surgery with great interest, I absolutely agree with the authors that the resear...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Journal of Preventive Medicine
سال: 2023
ISSN: ['2330-8230', '2330-8222']
DOI: https://doi.org/10.11648/j.ejpm.20231101.12