Study of Floating Column in Multistory Building Subjected to Seismic Load using Pushover Analysis
نویسندگان
چکیده
منابع مشابه
Performance-Based Seismic Assessment of Shallow Tunnels Using Pushover Analysis
این مقاله قصد دارد که با استفاده از تحلیل بارافزون به تحلیل لرزه ای بر مبنای عملکرد پوشش تونل های کم عمقی که در خاک ساخته شده اند و تحت بارگذاری موج برشی قائم قرار گرفته اند بپردازد. تحلیل بارافزون یک تحلیل استاتیک غیرخطی است که بر اساس جابجا کردن جانبی مدل دو بعدی خاک و تونل عمل میکند. این تحلیل تنها مود تغییر شکل اعوجاج (رکینگ) مقطع عرضی پوشش تونل را ارزیابی میکند و نسبت به سایر روشهای عددی...
متن کاملIdentification of the Response of a Controlled Building Structure Subjected to Seismic Load by Using Nonlinear System Models
The present study investigates the prediction efficiency of nonlinear system-identification models, in assessing the behavior of a coupled structure-passive vibration controller. Two system-identification models, including Nonlinear AutoRegresive with eXogenous inputs (NARX) and adaptive neuro-fuzzy inference system (ANFIS), are used to model the behavior of an experimentally scaled three-story...
متن کاملMoving Load Analysis of Submerged Floating Tunnels
The concept of floating submerged tunnels becomes increasingly attractive idea to cross the straits. The structural solution in these bridges includes buoyancy force on tunnel body plus tension in mooring tethers. This paper investigates the effect of submergence on the dynamic response of submerged floating tunnels due to moving load. The inertial effect of the fluid on the submerged structure...
متن کاملA Study of Dynamic Characteristics of a Multistory Building Using Ambient Vibration Tests (TECHNICAL NOTE)
Dynamic characteristics of a typical multistory building in Iran have been studied in two different stages of building construction, using ambient vibration tests. Finite element models have also been used to determine these characteristics and to verify test results. The results indicated the agreements and also differences between conventional theoretical models and the behaviour of real stru...
متن کاملModal Pushover Seismic Analysis of Sac Buildings excluding Gravity Loads
Evaluated is the accuracy of the modal pushover analysis in estimating the seismic demands for six SAC buildings, excluding gravity-loads and P-delta effects. These results are compared with those obtained by nonlinear response history analysis and three force distributions in FEMA-273.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal for Research in Applied Science and Engineering Technology
سال: 2020
ISSN: 2321-9653
DOI: 10.22214/ijraset.2020.30785