Study of Echo planar Method for abdominal imaging
نویسندگان
چکیده
منابع مشابه
Effect of contrast media on single-shot echo planar imaging: implications for abdominal diffusion imaging.
PURPOSE The goal of this study was to determine the effect of contrast media on the signal behavior of single-shot echo planar imaging (ssEPI) used for abdominal diffusion imaging. MATERIALS AND METHODS The signal of an ssEPI spin echo sequence in a water phantom with varying concentrations of gadolinium was modeled with Bloch equations and the predicted behavior validated on a phantom at 1.5...
متن کاملEcho-planar imaging.
Echo-planar imaging is a fast magnetic resonance (MR) imaging technique that allows acquisition of single images in as little as 20 msec and performance of multiple-image studies in as little as 20 seconds. Echo-planar imaging achieves its speed by obtaining all spatial-encoding information after a single radio-frequency (RF) excitation. Conventional imaging requires multiple-RF excitations, se...
متن کاملGhost-Free Spin-Echo Echo Planar Imaging Method for Diffusion Weighted Images using Adaptive RF Pulses
Y. Han, J. Hwang, J-Y. Chung, H. Park Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Korea, Republic of Introduction Diffusion tensor imaging (DTI) can provide valuable information regarding brain connectivity and neurological diseases. However, acquiring DTI is not an easy process because it has to be acquired in a short period of time with h...
متن کاملReferenceless interleaved echo-planar imaging.
Interleaved echo-planar imaging (EPI) is an ultrafast imaging technique important for applications that require high time resolution or short total acquisition times. Unfortunately, EPI is prone to significant ghosting artifacts, resulting primarily from system time delays that cause data matrix misregistration. In this work, it is shown mathematically and experimentally that system time delays...
متن کاملEcho-planar imaging of intravoxel incoherent motion.
The recently established single-shot technique of echo-planar imaging of intravoxel incoherent motion (IVIM) for determining and imaging the variations of microscopic motions of water has been applied to studies of water perfusion in phantoms and to in vivo studies of diffusion and perfusion in cat and human brains. The phantom results demonstrate that perfusion levels comparable with those fou...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1997
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00001355860