[Mechanical studies on casting titanium alloy denture base].
The mechanical properties of the Akers type clasp, bar and frame made by the newly developed Ti-20Cr-0.2Si alloy were studied in order to obtain the indices for designing the cast partial denture base. In the case of the clasp, the bending strength of the Ti-20Cr-0.2Si alloy and pure Ti was lower than that of the Co-Cr alloy. The Ti-20Cr-0.2Si alloy and pure Ti may have the same retentive force...
متن کاملEffect of Stone Cast Type on Complete Denture Base Adaptation
Introduction: Few researches have been conducted researches on the influence of the type of dental stone used for fabrication of casts on the adaptation of denture bases. The purpose of this study was to compare the effect of two types of stone casts on the accuracy of fit in complete denture bases. Methods: Using sixty fully replicated master casts obtained by duplicating a metal die represent...
متن کاملHydrophilic surface modification of acrylic denture base material by silica coating and its influence on Candida albicans adherence.
Silica coating modifies hydrophobic denture base materials to have a hydrophilic surface. The purpose of this study was to evaluate the effect of silica coating to a denture base material on resistance to Candida albicans (C. albicans) adherence. Specimens were prepared by polymerizing an acrylic denture lining material and polished using silicon carbide paper up an abrasive grade of 1000. The ...
متن کاملBasic studies on visible light-cured resin as a denture base. Part 17. Transverse and tensile strengths of repaired denture base resin using a trial repair resin.
Trial production of a visible light-cured repair resin (powder/liquid type, TPL) as a denture base resin was carried out using cyclophosphazene monomer, and then the transverse and tensile strengths of the repaired specimens were examined. As a control, Triad Gel (TRI) was used. In the transverse strength test, TPL showed values of 507-470 kgf/cm2, which were about double those of TRI. As for t...
متن کاملThe calibration of flask press spring loads for studies on the properties of denture base resins.
A simple technique is described for the rapid and accurate calibration of flask press spring loads for studies in which denture base resins require to be processed under uniform loading conditions. The technique was evaluated in com mercially available flask presses and was found to perform with a high degree of precision. It offers a simple solution to the problem of standardising flask press...