Studies of uniformity of 50 μm low-gain avalanche detectors at the Fermilab test beam
نویسندگان
چکیده
منابع مشابه
CALICE ScECAL Beam Test at Fermilab
The scintillator-strip electromagnetic calorimeter (ScECAL) is one of the calorimeter technologies which can achieve fine granularity required for the particle flow algorithm. Second prototype of the ScECAL has been built and tested with analog hadron calorimeter (AHCAL) and tail catcher (TCMT) in September 2008 at Fermilab meson test beam facility. Data are taken with 1 to 32 GeV of electron, ...
متن کاملanalysis of reading comprehension needs of the students of paramedical studies: the case of the students of health information management (him)
چکیده ندارد.
15 صفحه اولexploring motivation and english test preparation strategies of iranian pre-university candidates during and at the end of test preparation period for konkur examination
the current study aimed at investigating the relationship between motivation and test preparation strategies (tpss) used by iranian pre-university students in their preparation period for the university entrance exam (uee). due to the importance of uee in iran, this study also attempted to show its impact on these two important variables. to this end, 100 pre-university students in an iranian p...
Transverse and longitudinal beam dynamics studies at the Fermilab photoinjector
The Fermilab photoinjector produces electron bunches of 1–12 nC charge with an energy of 16–18 MeV. Detailed measurements and optimization of the transverse emittance have been carried out for a number of beam line optics conditions, and at a number of beam line locations. The length of the bunches has also been measured, first for an uncompressed beam (as a function of the charge) and then for...
متن کاملconstruction and validation of the translation teacher competency test and the scale of students’ perceptions of translation teachers
the major purpose of this study was to develop the translation teacher competency test (ttct) and examine its construct and predictive validity. the present study was conducted in two phases: a qualitative phase as well as a quantitative phase. in the first phase of the study, the author attempted to find out the major areas of competency required for an academic translation teacher. the second...
ذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 2018
ISSN: 0168-9002
DOI: 10.1016/j.nima.2018.03.074