Studies of Low-energy Converging Collimator
نویسندگان
چکیده
منابع مشابه
Converging free energy estimates: MM-PB(GB)SA studies on the protein-protein complex Ras-Raf
Estimating protein-protein interaction energies is a very challenging task for current simulation protocols. Here, absolute binding free energies are reported for the complex H-Ras/C-Raf1 using the MM-PB(GB)SA approach, testing the internal consistency and model dependence of the results. Averaging gas-phase energies (MM), solvation free energies as determined by Generalized Born models (GB/SA)...
متن کاملA parallel-cone collimator for high-energy SPECT.
UNLABELLED In SPECT using high-energy photon-emitting isotopes, such as (131)I, parallel-hole collimators with thick septa are required to limit septal penetration, at the cost of sensitivity and resolution. This study investigated a parallel-hole collimator with cone-shaped holes, which was designed to limit collimator penetration while preserving resolution and sensitivity. The objective was ...
متن کاملStudies of structure functions at a low - energy facility
We discuss the studies on structure functions at the possible future RCNP facility. At this stage, an electron-proton or proton-proton collider with √ s = 5 ∼ 10 GeV is considered. We explain large-x physics, nuclear modification of sea-quark and gluon distributions, and tensor spin structure function as the interesting topics at the facility. The large-x parton distributions are important for ...
متن کاملExperimental studies of neutral current pion production at low energy
The unknown neutrino mixing angle θ13 is one of the most important goals in current neutrino experiments. For the next generation of long baseline neutrino oscillation experiments, T2K and NOvA, the precise measurement of neutrino-nucleus cross sections in the few GeV energy range is an essential ingredient in the interpretation of neutrino oscillation signals. Neutral current neutral-pion prod...
متن کاملImproved Detection of Sentinel Lymph Nodes in SPECT/CT Images Acquired Using a Low- to Medium-Energy General-Purpose Collimator.
PURPOSE The use of the low-energy high-resolution (LEHR) collimator for lymphoscintigraphy causes the appearance of star-shaped artifacts at injection sites. The aim of this study was to confirm whether the lower resolution of the low- to medium-energy general-purpose (LMEGP) collimator is compensated by decrease in the degree of septal penetration and the reduction in star-shaped artifacts. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RADIOISOTOPES
سال: 1978
ISSN: 1884-4111,0033-8303
DOI: 10.3769/radioisotopes.27.39