Structural response of concrete-filled elliptical steel hollow sections under eccentric compression
نویسندگان
چکیده
منابع مشابه
Flexural Performance of High-strength Prestressed Concrete-encased Concrete-filled Steel Tube Sections
The sections composed of concrete and steel, which include concrete-encased concrete-filled tubes, generally have defects due to the low tensile strength of concrete. Therefore, an appropriate method was used for the combination of concrete-filled tubes (CFT) and prestressing strands which is encased in concrete. The conventional design guidelines are commonly developed for materials with norma...
متن کاملExperimental and Numerical Study on Bar-Reinforced Concrete Filled Steel Tubular Columns Under Axial Compression
The behaviors of bar-reinforced concrete filled steel tubular columns subjected to axial load were studied. One plain concrete filled steel tubular column and three bar-reinforced concrete filled steel tubular columns were tested. The deformation of specimens and the strain of steel tubes were measured. Based on experimental researches, a simple numerical analysis method was presented to simula...
متن کاملA unified formulation for circle and polygon concrete-filled steel tube columns under axial compression
Current design practice of concrete-filled steel tube (CFST) columns uses different formulas for different section profiles to predict the axial load bearing capacity. It has always been a challenge and practically important issue for researchers and design engineers who want to find a unified formula that can be used in the design of the columns with various sections, including solid, hollow, ...
متن کاملAnalysis of Thin-Walled Steel Sections Filled with Concrete Using Non-Linear Finite Element Method
Being economical and performing well under cyclic loads, steel sections filled with concrete have been widely used in structural buildings. Extensive studies and experiments have been conducted to investigate the influence of different parameters and loadings on the behavior of these structural components. Based on the data available from previous experiments and studies, this paper discusses t...
متن کاملBehaviour of FRP strengthened concrete columns under eccentric compression loading
This paper presents results of testing eccentrically loaded columns externally wrapped with two types of materials. Six cylindrical (205 mm diameter and 925 mm height) plain columns were cast and tested. Half of the columns were wrapped with GFRP and the other half with CFRP. All columns were tested by applying an axial load at 50 mm eccentricity. In each group (GFRP or CFRP wrapped) of columns...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2012
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2012.06.040