Structural Performance of PC Double Beam–Column Connection Under Gravity and Seismic Loading

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of Glass Panels Under Seismic Loading

The primary goal of this thesis is to analyze current trends in the improvement of the performance and safety of glass during an earthquake. The four sections consist of an overview of glass as a building material, glass installation methods, rehabilitation methods for existing structures, and building code related issues. The thesis is based on an analysis of sources including books, journal a...

متن کامل

PERFORMANCE BASED DESIGN OPTIMIZATION OF STEEL MOMENT RESISTING FRAMES INCORPORATING SEISMIC DEMAND AND CONNECTION PARAMETERS UNCERTAINTIES

One of the most important problems discussed recently in structural engineering is the structural reliability analysis considering uncertainties. To have an efficient optimization process for designing a safe structure, firstly it is required to study the effects of uncertainties on the seismic performance of structure and then incorporate these effects on the optimization process. In this stud...

متن کامل

Seismic Behavior of Prefabricated Column-Footing Connection

Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specim...

متن کامل

Seismic Performance of Square RC Bridge Columns under Combined Loading including Torsion with Low Shear

During earthquake excitations, reinforced concrete bridge columns can be subjected to a combination of axial load, shear force, flexural moments, and torsional moments. The torsional moment can be much more significant in columns of bridges that are skewed, curved, have unequal spans, or unequal column heights. Combined loading including torsion can result in complex flexural and shear failure ...

متن کامل

Effect of column-foundation connection stiffness on seismic performance of rocking steel braced frame

Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Concrete Structures and Materials

سال: 2020

ISSN: 1976-0485,2234-1315

DOI: 10.1186/s40069-020-00439-4