Structural Performance of Isolated Steel Beam-to-Column Connection
نویسندگان
چکیده
منابع مشابه
Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کاملEffect of column-foundation connection stiffness on seismic performance of rocking steel braced frame
Residual drifts after severe earthquakes interrupt serviceability of buildings. Retrofitting of such buildings is in many cases very difficult and consumes lots of time and money. Recently, there are some attempts to develop the seismic design procedures to not only satisfy life safety criteria but also lead to more economical buildings. One of these modern methods of improving seismic performa...
متن کاملNonlinear Numerical Analyses of a Fabricated Connection of Concrete-Filled Steel Column to Steel Beam Under Low-Reversed Cyclic Loading
RESEARCH ARTICLE Nonlinear Numerical Analyses of a Fabricated Connection of Concrete-Filled Steel Column to Steel Beam Under Low-Reversed Cyclic Loading Chunyi Cui, Kun Meng, Yan Kong, Yannian Zhang and Wenxin Zuo Department of Civil Engineering, Dalian Maritime University, Dalian 116026, China School of Civil Engineering, Shenyang Jianzhu University, Shenyang 110168, China School of Civil and ...
متن کاملDamage Avoidance Design Steel Beam-Column Moment Connection Using High-Force-To-Volume Dissipators
Existing welded steel moment frames are designed to tolerate substantial yielding and plastic rotation under earthquake loads. This sacrificial design approach can lead to permanent, and often irreparable damage when interstory drifts exceed 2%. The experimental seismic performance of a 50% full-scale damage avoidance designed structural steel beam-column connection is presented. The beamcolumn...
متن کاملFinite element analysis of a rigid beam to column connection reinforced with channels
Abstract: This research work presents a new rigid connection constructed with channels. In order to assess its hysteresis behavior, three specimens with different cover plates and six specimens with different panel zone thickness have been considered. The energy absorbed by the connection and the behavior of the panel zone were studied during cyclic loading and compared with those of connectio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Civil Engineering and Architecture
سال: 2018
ISSN: 2328-398X
DOI: 10.12691/ajcea-6-2-4