Structural behaviour of T-Perfobond shear connectors in composite girders: An experimental approach
نویسندگان
چکیده
منابع مشابه
Structural Performance of Steel Pile Caps Strengthened with Perfobond Shear Connectors under Lateral Loading
The conventional strengthening strategy on the connection between the steel pile cap and reinforced concrete footing requires a series of complicated processes such as the distribution of reinforcing bars, their anchorage into concrete, and the usage of shear keys. This study investigates the structural performance of steel pile caps strengthened with newly proposed perfobond shear connectors s...
متن کاملAnalysis of the Shear Behavior of Stubby Y-Type Perfobond Rib Shear Connectors for a Composite Frame Structure
Shear connectors are used in steel beam-concrete slabs of composite frame and bridge structures to transfer shear force according to design loads. The existing Y-type perfobond rib shear connectors are designed for girder slabs of composite bridges. Therefore, the rib and transverse rebars of the conventional Y-type perfobond rib shear connectors are extremely large for the composite frames of ...
متن کاملBehaviour of Corroded Single Stud Shear Connectors
In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested. The test specimens were firstly corroded to different corrosion rates by the electronic accelerating method. Static load...
متن کاملBehaviour of Corroded Stud Shear Connectors under Fatigue Loading
Experimental investigation was conducted on corroded composite push-out specimens to study the behavior of shear studs subjected to fatigue loading. A total of eight standard EC4 push-out specimens were tested. The expected corrosion rate of test specimens ranged from 0 to 50%. The main purpose of these tests was to determine the fatigue life and the reduction effect caused by the corrosion on ...
متن کاملInvestigation of channel shear connectors for composite concrete and steel T-beam
This paper evaluates the behavior of channel shear connectors, embedded in a concrete slab, with different concrete materials. The results of a series of limited push-out specimens were presented and discussed. The push-out tests comprise of channel shear connectors in different types of concrete. Reinforcement was included in some specimens, as well. The results showed that using reinforcement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2008
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2008.01.015