STRUCTURAL BEHAVIOUR OF REINFORCED CONCRETE SQUARE COLUMNS DAMAGED BY REBAR CORROSION
نویسندگان
چکیده
منابع مشابه
Residual strength of blast damaged reinforced concrete columns
Columns are the key load-bearing elements in frame structures and exterior columns are probably the most vulnerable structural components to terrorist attacks. Column failure is normally the primary cause of progressive failure in frame structures. A high-fidelity physicsbased computer program, LS-DYNA was utilized in this study to provide numerical simulations of the dynamic responses and resi...
متن کاملFRP Repair of Corrosion-Damaged Reinforced Concrete Beams
Corrosion of steel reinforcement is one of the main durability problems facing reinforced concrete infrastructures worldwide. This paper will summarize the results of a multi-phase experimental program undertaken at the University of Waterloo to investigate the viability of using externally bonded fiber reinforced polymer (FRP) laminates to rehabilitate corrosion-damaged reinforced concrete bea...
متن کاملBoric Acid Corrosion of Concrete Rebar
Borated water leakage through spent fuel pools (SFPs) at pressurized water reactors is a concern because it could cause corrosion of reinforcement steel in the concrete structure and compromise the integrity of the structure. Because corrosion rate of carbon steel in concrete in the presence of boric acid is lacking in published literature and available data are equivocal on the effect of boric...
متن کاملRehabilitation of Reinforced Concrete Columns
In recent years, rehabilitation has been the subject of extensive research due to increased spending on building work and repair of built works. In all cases, it is absolutely essential to carry out methods of strengthening or repair of structural elements, and that following an inspection analysis and methodology of a correct diagnosis. The reinforced concrete columns are important elements in...
متن کاملStrengthening of Corrosion-Damaged Reinforced Concrete Beams with Glass Fiber Reinforced Polymer Laminates
Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP) laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal on Design and Manufacturing Technologies
سال: 2008
ISSN: 0973-9106
DOI: 10.18000/ijodam.70028