Abstract Glass fibers reinforced polymer (GFRP) were used to longitudinally and transversally 12 columns while the other 4 with steel or GFRP as reference specimens. This research dealt several parameters under different loading conditions, such reinforcing material spacing between ties. study aims find out ability of bear loads. In addition, investigate mode failure in these their appropriateness structures since are compression members. The tested results revealed that concentric give higher resistance than eccentrically loaded counterparts. Also, hybrid column (steel GFRP) had highest peak load compared fully columns. RC- an ultimate slightly less its counterpart same condition.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FRP Composites Strengthening of Concrete Columns under Various Loading Conditions

This paper provides a review of some of the progress in the area of fiber reinforced polymers (FRP)-strengthening of columns for several loading scenarios including impact load. The addition of FRP materials to upgrade deficiencies or to strengthen structural components can save lives by preventing collapse, reduce the damage to infrastructure, and the need for their costly replacement. The ret...

متن کامل

Theoretical model for slender FRP-confined circular RC columns

An important application of fiber-reinforced polymer (FRP) composites is to provide confinement to reinforced concrete (RC) columns to enhance their loadcarrying capacity. However, this application is generally restricted to short columns as existing design guidelines do not contain provisions for the design of FRP jackets for slender columns. This situation has been due to both the scarcity of...

متن کامل

Time-Dependent Structural Behavior of Repaired Corroded RC Columns Located in a Marine Site

The chloride corrosion of reinforcing steel in reinforced concrete (RC) structures is a significant reason for premature deterioration and failure of RC structures in aggressive environments such as Persian Gulf region. This is one of the most important sources of engineering and economic problems in developed countries. So, the repair and maintenance of RC structures exposed to corrosive envir...

متن کامل

Experimental and numerical study on the structural behavior of eccentrically loaded GFRP columns

Glass fiber reinforced polymer (GFRP) pultruded profiles are being increasingly used in civil engineering applications. Although they offer several advantages over traditional materials, such as high strength, lightness and non-corrodibility, GFRP profiles present low elasticity and shear moduli, which together with their slender walls makes them very prone to buckling phenomena. Several previo...

متن کامل

Seismic Performance of Square RC Bridge Columns under Combined Loading including Torsion with Low Shear

During earthquake excitations, reinforced concrete bridge columns can be subjected to a combination of axial load, shear force, flexural moments, and torsional moments. The torsional moment can be much more significant in columns of bridges that are skewed, curved, have unequal spans, or unequal column heights. Combined loading including torsion can result in complex flexural and shear failure ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Civil and Environmental Engineering

سال: 2023

ISSN: ['1336-5835', '2199-6512']

DOI: https://doi.org/10.2478/cee-2023-0001