Strengthening Solutions for Deep Reinforced Concrete Beam with Cutout Opening
نویسندگان
چکیده
Since reinforced concrete (RC) buildings have long service life, cutout openings are generally needed in their load-bearing walls as a sustainable solution order to meet new requirements of users. However, the decrease capacity walls, which may result failure buildings. In this paper, we investigate possibility making door opening RC wall an existing building Gävle Sweden. The studied current paper rests on two individual supports at its ends; thus, it is considered deep beam. called examined (EW) here. StruSoft FEM-Design software used study model, analyze, and design based Eurocodes Swedish national annex. potential need for EW be strengthened when made also evaluated. It concluded that strengthening with needed. Different solutions proposed EW. Moreover, situation assessed regard utilization ratio, deflection, weight. Consequently, demonstrated function well
منابع مشابه
Experimental and Analytical Study on Reinforced Concrete Deep Beam
ABSTRACT: Several reinforced concrete deep beams with different L/D ratios (1.5, 1.6, 1.71) were cast and tested in order to investigate the strain distribution pattern at mid-section of the beam. This paper describes analysis of deep beams subjected to two point loading with three different L/D ratios (1.5, 1.6, 1.71) using Non-linear Finite element method (ANSYS 9.0 software). In ANSYS 9.0 so...
متن کاملShear strengthening of reinforced concrete beams with CFRP
The current paper reviews existing design guidelines for strengthening beams in shear with carbon fibre reinforced polymer (CFRP) sheets and proposes a modification to Concrete Society Technical Report TR55. It goes on to present the results of an experimental programme which evaluated the contribution of CFRP sheets towards the shear strength of continuous reinforced concrete (RC) beams. A tot...
متن کاملStrengthening of Corrosion-Damaged Reinforced Concrete Beams with Glass Fiber Reinforced Polymer Laminates
Problem statement: This study showed the results of an experimental investigation on the strengthening of corrosion damaged reinforced concrete beams with unidirectional cloth glass fiber reinforced polymer (UDCGFRP) laminates. Approach: All the beam specimens 150×250×3000 mm were cast and tested for the present investigation. One beam specimen was neither corroded nor strengthened to serve as ...
متن کاملStrengthening reinforced concrete T connections by steel straps
The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...
متن کاملComputer-Aided Strengthening of Steel and Reinforced Concrete Telecommunication Poles
ABSTRACT: The absence of explicit guidelines for the rehabilitation of existing pole structures was the motivation to investigate the effectiveness of steel jacketing for the retrofitting of self-supporting steel and reinforced concrete telecommunication poles. The present study describes a numerical simulation of preand post-retrofitted conditions of the pole structures subjected to seismic ha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Buildings
سال: 2021
ISSN: ['2075-5309']
DOI: https://doi.org/10.3390/buildings11080370