Strengthening of Coupled Shear Walls – An overview
نویسندگان
چکیده
Coupling beams are considered one of the most important structural elements due to their vital role in resisting lateral loads by improving overall building stiffness and reducing impact overturning. The resistance coupled shear walls (CSWs) earthquakes depends on coupling beam (CB) for enhancing ductility system energy absorption capacity. There two main types beams; diagonally reinforced conventionally ones. In case diagonal reinforcement, which is being currently recommended new design codes, more efficient consolidating providing better performance earthquakes. On other hand, reinforcing configuration showed some difficulties terms construction. already existing buildings that have beams, were designed according old codes. These extreme need strengthening resist Therefore, studies been conducted find an alternative scheme walls. methods differed whether using steel plates or fibre-reinforced polymers sheets. Nowadays Fibre Reinforced Polymers (FRP) widely used strengthen improve behaviour This paper presents a summary available literature concerning FRP. Strengthening method, configurations, failure modes, test setups summarized.
منابع مشابه
Response Modification Factor of Coupled Steel Shear Walls
The present research is concerned with the determination of ductility, over-strength and response modification factors of coupled steel shear wall frames. Three structural models with various numbers of stories, bay width and coupling beam height were analyzed using static pushover and incremental nonlinear dynamic analyses. The ductility, over-strength and response modification factors for the...
متن کاملShear Strengthening of Urm Clay Walls with Frp Systems
This paper presents an experimental program dealing with the shear strengthening with FRP systems of URM walls built with concrete and clay units. Ten concrete and five clay masonry panels, strengthened with FRP composites in the form of laminates and rods, and stainless steel, were loaded along the wall diagonal to observe their shear performance. The dimension of the concrete masonry panels w...
متن کاملresponse modification factor of coupled steel shear walls
the present research is concerned with the determination of ductility, over-strength and response modification factors of coupled steel shear wall frames. three structural models with various numbers of stories, bay width and coupling beam height were analyzed using static pushover and incremental nonlinear dynamic analyses. the ductility, over-strength and response modification factors for the...
متن کاملevaluation of coupled- shear walls subjected to near-field earthquakes
coupled -shear walls are one of lateral load resisting systems in high and medium rise reinforced concrete buildings. the lateral structural response is exactly dependents on the shear walls behavior; therefore these elements must response well whenundergodifferent load conditions. the structures located in near-source region behave differently compared to those in near-source sites when subjec...
متن کاملresponse of coupled-precast shear walls subjected to cyclic loads
large panel precast structures are analyzed based on the connection rigidity. however, the connections undergo nonlinear and inelastic response, when subjected to seismic loads. thus, to study the actual behavior of structure, the connection nonlinearity should be implemented in the joints. in this paper, three conventional connection types are modeled based on the envelope of their cyclic resp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Egyptian International Journal of Engineering Sciences and Technology (Print)
سال: 2021
ISSN: ['2682-3640', '1687-8493']
DOI: https://doi.org/10.21608/eijest.2021.84572.1079