Strength of eccentrically loaded slender columns made with high-strength concrete
نویسندگان
چکیده
منابع مشابه
Fire behavior of axially loaded slender high strength concrete - filled tubular columns
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns ...
متن کاملPerformance of High-strength Concrete Made with Recycled Ceramic Aggregates
Recent scientific concerns to achieve sustainability in construction have suggested the implementation of using recycled aggregate in concrete because it has the potential to reduce the demand for extraction of natural raw materials and decrease the volume of wastes landfilled. In this respect, this study aims to investigate the suitability of using ceramic tile (CT) and ceramic sanitary (CS) w...
متن کاملAmbient and fire behaviour of eccentrically loaded elliptical slender concrete-filled tubular columns
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high te...
متن کاملBehavior of High-Strength Concrete Rectangular Columns
This paper summarizes the test results of an extensive research program sponsored by the US Transportation Research Board of the National Research Council to examine the behavior of high-strength concrete rectangular columns subjected to concentric and eccentric loading conditions. The variables considered in this investigation were concrete strength ranging from 7.9 ksi (55 MPa) to 16.5 ksi (1...
متن کاملBond of High Strength Concrete with High Strength Reinforcing Steel
This paper presents a study about the bond of high strength concrete with high strength steel. Fourteen pull out tests were carried out to determine the bond. The concrete strength was about 70 MPa and the steel was a 500 MPa grade. Bar diameters used were 12, 16, 20, 25, 28, 32 and 36 mm. In order to investigate the effect of cover, each test was done twice, once in a 240 mm diameter concrete ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Proceedings of the Institution of Civil Engineers - Structures and Buildings
سال: 2021
ISSN: 0965-0911,1751-7702
DOI: 10.1680/jstbu.19.00064