Strategies to minimize beam and sample vibration-induced instabilities at the microfocus MX XAIRA beamline at ALBA

نویسندگان

چکیده

Abstract The performance of microfocus beamlines, and ultimately the quality diffraction data, is very sensitive to vibrations affecting optical elements sample stages holder. We report here strategies applied in design MX XAIRA beamline at ALBA synchrotron mitigate effects two relevant sources vibrations: circulation LN 2 flow evacuate thermal load on monochromator cryocooling gas stream being blown sample. internal shape size cooling pads that clamp optics have been designed minimize turbulences liquid nitrogen while maximizing heat transfer. Computational Fluid Dynamics (CFD) simulations some preliminary metrology tests are presented. Besides, end-station, cryo-cooler blowing typically a 5-10 L/min or helium 100K sample, inducing micron range. optimal geometrical configuration between holder cryocooler has assessed by means CDF tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The ID23-2 structural biology microfocus beamline at the ESRF

The first phase of the ESRF beamline ID23 to be constructed was ID23-1, a tunable MAD-capable beamline which opened to users in early 2004. The second phase of the beamline to be constructed is ID23-2, a monochromatic microfocus beamline dedicated to macromolecular crystallography experiments. Beamline ID23-2 makes use of well characterized optical elements: a single-bounce silicon (111) monoch...

متن کامل

Developments in optics and performance at BL13-XALOC, the macromolecular crystallography beamline at the Alba Synchrotron

BL13-XALOC is currently the only macromolecular crystallography beamline at the 3 GeV ALBA synchrotron near Barcelona, Spain. The optics design is based on an in-vacuum undulator, a Si(111) channel-cut crystal monochromator and a pair of KB mirrors. It allows three main operation modes: a focused configuration, where both mirrors can focus the beam at the sample position to 52 µm × 5.5 µm FWHM ...

متن کامل

exploring motivation and english test preparation strategies of iranian pre-university candidates during and at the end of test preparation period for konkur examination

the current study aimed at investigating the relationship between motivation and test preparation strategies (tpss) used by iranian pre-university students in their preparation period for the university entrance exam (uee). due to the importance of uee in iran, this study also attempted to show its impact on these two important variables. to this end, 100 pre-university students in an iranian p...

Microfocusing at the PG1 beamline at FLASH

The Kirkpatrick-Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best p...

متن کامل

the relationship between multiple intelligences and english proficiency of efl learners at payame noor university

این پژوهش برای بررسی پیوند احتمالی میان هوش های چندگانه – پیشنهاد شد? هاوارد گاردنر، 1983– (هم به گونه یکپارچه و هم به گونه بند بند) از یک سو و توانش انگلیسی دانشجویان ایرانی دانشگاه پیام نور در رشته زبان انگلیسی از سوی دیگر انجام گرفت. برای این کار، تافلpbt و پرسش نامه هوش های چندگانه میان 102 دانشجو در دانشگاه پیام نور شهریار پخش شد. نتایج بررسی داده ها نشان می دهد که در اندازه معنا داری 5 در...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of physics

سال: 2022

ISSN: ['0022-3700', '1747-3721', '0368-3508', '1747-3713']

DOI: https://doi.org/10.1088/1742-6596/2380/1/012073