Low-cost Vector Network Analyzer for Biomedical Applications
A low-cost and portable vector network analyzer (VNA) which covered operating frequency between 1MHz to 3GHz is used for vector reflection coefficient and standing wave ratio (swr) of the various microstrip antennas. This paper presents measurements of various ultra wideband (uwb) microstrip antennas for applications in biomedical field. Selection of antenna is an important key for detection of...
متن کاملA Vector Network Analyzer Based on Seven-Port Wave-Correlator
A seven-port wave-correlator based vector network analyzer is proposed. The seven-port wave-correlator is a combination of two six-port wave-correlators which share common components. Furthermore, the complex wave ratio measurement accuracy is improved since the input signals can be directly detected by the side-arm ports. A seven-port wave-correlator is fabricated using microstrip branch line ...
متن کاملVector-Network-Analyzer Calibrations
We develop an uncertainty analysis that captures the dominant sources of measurement error in state-of-the-art WM-380 (WR 1.5) rectangular-waveguide vector-network-analyzer measurements over the frequency range 500–750 GHz. We use the analysis to assess thru-reflect-line, thru-short-match, and thru-short-radiating-open calibrations. The comparison shows that thru-short-match and thru-short-radi...
متن کاملElectronic Vector - Network - Analyzer Verification ■
118 October 2009 Digital Object Identifier 10.1109/MMM.2009.933595 The National Institute of Standards and Technology (NIST) recently introduced a new electronic approach for verifying microwave vectornetwork-analyzer (VNA) calibrations with a single computer-controlled electronic verifi cation artifact. The verifi cation results are captured in easy-tounderstand performance metrics that, unlik...
متن کاملSeven State PTP for Vector Network Analyzer
A new, seven-state switched perturbation twoport (PTP) for vector reflection measurement based on scalar measurement only was designed and realized in microstrip structure using PIN diodes. The structure was experimentally tested by means of vector measurements of different impedances in frequency band with relative bandwidth of 2.5 octaves. Good agreement with data obtained using a precise vec...