Strain distribution in the proximal human femur

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compression or tension? The stress distribution in the proximal femur

BACKGROUND Questions regarding the distribution of stress in the proximal human femur have never been adequately resolved. Traditionally, by considering the femur in isolation, it has been believed that the effect of body weight on the projecting neck and head places the superior aspect of the neck in tension. A minority view has proposed that this region is in compression because of muscular f...

متن کامل

Strain distribution in the proximal human femur. An in vitro comparison in the intact femur and after insertion of reference and experimental femoral stems.

Six pairs of human cadaver femora were divided equally into two groups one of which received a non-cemented reference implant and the other a very short non-dependent experimental implant. Thirteen strain-gauge rosettes were attached to the external surface of each specimen and, during application of combined axial and torsional loads to the femoral head, the strains in both groups were measure...

متن کامل

Elastic Properties of the Human Proximal Femur

This chapter examines the effects of femoral neck geometry and topological structure on elastic properties. A finite element code is used to calculate the full elastic tensor for thirteen human proximal femur specimens. We show that the micro-structure within the human femoral neck and head gives rise to approximate orthotropic elastic symmetry at the whole bone scale. The finite element code c...

متن کامل

Load distribution in the healthy and osteoporotic human proximal femur during a fall to the side.

Due to remodeling of bone architecture, an optimal structure is created that minimizes bone mass and maximizes strength. In the case of osteoporotic vertebral bodies, however, this process can create over-adaptation, making them vulnerable for non-habitual loads. In a recent study, micro-finite element models of a healthy and an osteoporotic human proximal femur were analyzed for the stance pha...

متن کامل

Mapping the strain distribution on the proximal femur with titanium and flexible-stemmed implants using digital image correlation.

We implanted titanium and carbon fibre-reinforced plastic (CFRP) femoral prostheses of the same dimensions into five prosthetic femora. An abductor jig was attached and a 1 kN load applied. This was repeated with five control femora. Digital image correlation was used to give a detailed two-dimensional strain map of the medial cortex of the proximal femur. Both implants caused stress shielding ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Bone and Joint Surgery. British volume

سال: 2001

ISSN: 0301-620X,2044-5377

DOI: 10.1302/0301-620x.83b2.0830295