A straight endotracheal connection.
THE connection illustrated (fig. 1) has been found useful when administering anaesthetics in the following circumstances : FIG. 2 It is probable that the idea of a similar connection has occurred to others. No mention of one, however, could be found in the literature nor did the anaesthetic instrument firms know of one. The screw Fio. 1 Cranial Angiography. Here (fig. 2) it is essential that th...
متن کاملA perforated endotracheal connection piece.
Basically this is a Rowbotham type connection piece with elongated stem in which the perforations have been made. A rotating inner drum with matching perforations allows partial or complete occlusion of the holes when necessary. The internal diameter of the stem is the same as in a standard Rowbotham piece. I have used the connection in clinical practice for over twelve months and have found it...
متن کاملFacilitating GlideScope intubation with the straight end of an endotracheal tube introducer.
or respiratory compromise. However, on sternotomy incision, the infant experienced sudden treatable ventricular fibrillation, likely a result of his tenuous cardiac status. Complete repair of the total anomalous pulmonary venous return occurred. He was extubated on postoperative day three, and subsequent chest films showed significantly improved tracheal alignment. Further delineation of other ...
متن کاملEndotracheal extubation.
N Engl J Med 2014;370:e4. DOI: 10.1056/NEJMvcm1300964 Copyright © 2014 Massachusetts Medical Society. Overview Endotracheal extubation refers to the removal of an endotracheal tube from the trachea. This procedure is commonly performed in operating rooms, postanesthesia care units, and intensive care units. This review focuses on extubation of the trachea after general anesthesia and short-term...
متن کاملEndotracheal tube extubation force: adhesive tape versus endotracheal tube holder.
BACKGROUND Adhesive tape is commonly used to secure the endotracheal tube (ETT) in anesthesia and intensive-care settings. OBJECTIVE To determine the force required to extubate when the ETT is secured with adhesive tape or commercially available ETT holders. METHODS We orally intubated a simulation manikin with a standard 8.0-mm inner-diameter ETT, inflated the cuff to 20 cm H(2)O, and mea...