Stopping Power and Range for Proton Interaction with Lymph Tissues
نویسندگان
چکیده
In this paper, we calculated the mass stopping power (in MeV cm2/g) and range (cm) of proton in one types body tissues (lymph), from 1 Kev to 200 energy range. They are using Bethe Ziegler equations, SRIM program (version 2013) (Vol. 3) data by considering tissue composed several elements, so atomic number (Z) weight (A) for component meaning. The calculation results show that equation gives better than equation. However, terms loss tissue, four methods used approximately same.
منابع مشابه
Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiography.
A simple robust optimizer has been developed that can produce patient-specific calibration curves to convert x-ray computed tomography (CT) numbers to relative stopping powers (HU-RSPs) for proton therapy treatment planning. The difference between a digitally reconstructed radiograph water-equivalent path length (DRRWEPL) map through the x-ray CT dataset and a proton radiograph (set as the grou...
متن کاملQuantum mechanical proton range in human body
Introduction: Proton therapy delivers radiation to tumor tissue in a much more confined way than conventional photon therapy thus allowing the radiation oncologist to use a greater dose while still minimizing side. Materials and Methods: protons release most of their energy within the tumor region. As a result, the treating physician can potentially give an...
متن کاملstudy of dna interaction with ethylenediaminetetraacetic acid and sesamol food additives
برهمکنش dnaتیموس گاوی طبیعی (ct-dna) با اتیلن دی آمین تترااستات (edta)در بافرtris-hcl با 8/7 ph ( دراین ph،edta به نمک دی سدیم تبدیل می شود) وسسامول در بافر tris-hcl با4/7 ph مورد بررسی قرار گرفته است. edta و سسامول استفاده فراوانی در تکنولوژی غذایی و صنعت شیمیایی دارند. مدل اتصال dna مربوط بهedta بوسیله اسپکتروفتومتری جذب، دورنگ نمایی حلقوی(cd)، ویسکومتری وژل الکتروفورز بررسی شده است. طیفuv ...
15 صفحه اولRelative stopping power measurements to aid in the design of anthropomorphic phantoms for proton radiotherapy
The delivery of accurate proton dose for clinical trials requires that the appropriate conversion function from Hounsfield unit (HU) to relative linear stopping power (RLSP) be used in proton treatment planning systems (TPS). One way of verifying that the TPS is calculating the correct dose is an end-to-end test using an anthropomorphic phantom containing tissue equivalent materials and dosimet...
متن کاملSpencer-Attix water/medium stopping-power ratios for the dosimetry of proton pencil beams.
This paper uses Monte Carlo simulations to calculate the Spencer-Attix water/medium stopping-power ratios (sw, med) for the dosimetry of scanned proton pencil beams. It includes proton energies from 30 to 350 MeV and typical detection materials such as air (ionization chambers), radiochromic film, gadolinium oxysulfide (scintillating screens), silicon and lithium fluoride. Track-ends and partic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Environment, Engineering and Education
سال: 2021
ISSN: ['2656-8039']
DOI: https://doi.org/10.55151/ijeedu.v3i3.57