Stimulated emission depletion microscopy for biological imaging in four dimensions: A review
نویسندگان
چکیده
Stimulated emission depletion (STED) microscopy allows high lateral and axial resolution, long term imaging in living cells. Here we review recent technical advances STED microscopy, with emphasis on resolution measurement range of XYZt four dimensions. Different novel probes are discussed their respective application biological subcellular imaging. This may serve as a practical guide for choosing suitable approach to the advanced super-resolution
منابع مشابه
Stimulated emission depletion microscopy with optical fibers
Imaging at the nanoscale and/or at remote locations holds great promise for studies in fields as disparate as the life sciences and materials sciences. One such microscopy technique, stimulated emission depletion (STED) microscopy, is one of several fluorescence based imaging techniques that offers resolution beyond the diffractionlimit. All current implementations of STED microscopy, however, ...
متن کاملSupercontinuum stimulated emission depletion fluorescence lifetime imaging.
Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The ...
متن کاملSpectroscopic rationale for efficient stimulated-emission depletion microscopy fluorophores.
We report a rationale for identifying superior dyes for stimulated-emission depletion (STED) microscopy. We compared the dyes pPDI and pTDI, which displayed excellent photostability in single-molecule spectroscopy. Surprisingly, their photostability and performance in STED microscopy differed significantly. While single pTDI molecules could be visualized with excellent resolution (35 nm), pPDI ...
متن کاملDefining the Noise-limited-resolution for Stimulated Emission Depletion Microscopy
With recent developments in microscopy, such as stimulated emission deletion (STED) microscopy, far-field imaging at resolutions better than the diffraction limit is now a commercially available technique. Here, we analyse how the interplay between shot noise, thermal noise, the saturation intensity of a fluorescent label, and the damage threshold of the sample changes the maximum resolution of...
متن کاملSupraresolution Imaging in Brain Slices using Stimulated-Emission Depletion Two-Photon Laser Scanning Microscopy
Two-photon laser scanning microscopy (2PLSM) has allowed unprecedented fluorescence imaging of neuronal structure and function within neural tissue. However, the resolution of this approach is poor compared to that of conventional confocal microscopy. Here, we demonstrate supraresolution 2PLSM within brain slices. Imaging beyond the diffraction limit is accomplished by using near-infrared (NIR)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy Research and Technique
سال: 2021
ISSN: ['1097-0029', '1059-910X']
DOI: https://doi.org/10.1002/jemt.23750