Stiffness of Post-Tensioned Girderless Floor With Different Column Grids

نویسندگان

چکیده

The paper considers models of monolithic flat floor slabs with five spans in both directions. cell sizes are 6×6m, 6×9m, and 6×12m. calculation method is based on the application temperature load rope modeling rod elements. It shown that post-stressing should be used for slab side lengths over 7 m, as installation pre-stressed reinforcement shorter less feasible causes high economic costs.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing Repaired and Undamaged Specimens Test Results of Post-Tensioned Beam to Column Connections

Since, it is essential to provide homeless people by the earthquake with safe, habitable accommodation repairing medium and slight levels of damage at the connection parts should be undertaken. In order to prove that a repaired connection was sufficiently strong, a precast beam to column post tensioned connection was tested in three phases. In phase one, the middle level damage was observed at ...

متن کامل

Flexural Strengthening of Deficient Reinforced Concrete Beams with Post-Tensioned Carbon Composites using Finite Element Modelling

The application of external post-tensioned steel bars as an effective way to strengthen an existing bridge has been so far used in many different countries. In recent decades, however, they have been replaced by bars made from Carbon Fiber Reinforced Polymer (CFRP), as a material with high tensile strength and corrosion resistance, to address several concerns with steel bars such as their appli...

متن کامل

Experimental Study on Mechanical Property of Corner Columns Supported Reinforced Concrete Honeycombed-core Girderless Floor

In order to study the basic mechanical property of the new honeycombed-core girderless floor in cast-in-place reinforced concrete, and similarities and differences of the structural performance compared with traditional floor, we carried out the destructive stage loading test on large-scale corner columns supported reinforced concrete honeycombed-core girderless floor. And the thesis conducted ...

متن کامل

Ultimate Unbonded Tendon Stress in CFRP Strengthened Post-Tensioned Indeterminate I-Beams Cast with HSCs

Based on the bending experiment for two-span continuous post-tension beams with unbounded tendons and externally applied CFRP sheets, the analysis of the stress increment of unbonded tendons is monitored in the loading process. Since self-compacting concrete (SCC) is a suitable innovation,, understanding the implementation of this type of concrete on the ultimate unbonded tendon stress is criti...

متن کامل

Damage Detection in Post-tensioned Slab Using 2D Wavelet Transforms

Earthquake force, loading more than structural capacity, cracking, material fatigue and the other unpredicted events were undeniable in the structure life cycle in order that environmental conditions of the structure would be changed and treats health. Damage of structures such as crack, corrosion of the post tension cables from inappropriate grouting of the post tension structures and etc. can...