Stent Graft Repair of a Ruptured Aberrant Right Subclavian Artery after Open Repair
نویسندگان
چکیده
منابع مشابه
Stent Graft Repair of a Ruptured Aberrant Right Subclavian Artery after Open Repair
An aberrant right subclavian artery (ARSA) arising from the proximal portion of the descending thoracic aorta is the most common congenital anomaly of the aortic arch. This irregularity occurs in 0.51% of the population. Degenerative aneurysmal changes may occur in the proximal portion of an ARSA or at its aortic origin. This abnormal vessel passes posterior to the esophagus, and, in rare cases...
متن کاملOpen triple-branched stent graft applied to patient of acute type a aortic dissection with Aberrant Right Subclavian Artery
A 57-year-old Chinese male patient presented with Standford type A aortic dissection with an aberrant right subclavian artery (ARSA). At operation, the ascending aorta was replaced by a mono-branch vascular prosthesis with the branch bypassing to the ARSA; the triple-branched stent graft was inserted into the true lumen of the arch and proximal descending aorta (covering the origin of the ARSA)...
متن کاملThoracic aorta dissection associated with aberrant right subclavian artery: treatment with endovascular stent-graft placement.
Dissecting aneurysm is the condition produced by separation of the layers of the arterial wall by circulating blood. Although rare, the coexistence of aortic dissection and aberrant right subclavian artery may be catastrophic. In this study we report the endovascular treatment of a patient with thoracic aorta dissection associated with aberrant right subclavian artery. Aortic clamping proximal ...
متن کاملEndovascular Repair of Intra-thoracic Left Subclavian Artery Aneurysm with a Stent Graft
True aneurysms of the intra-thoracic portion of the subclavian artery are rare, comprising 3.5% of all peripheral aneurysms and the presence of associated aneurysms has been reported in as many as 46% of patients. The morbidity and mortality from standard surgical treatment is relatively high. Transluminal implantation of a covered stent graft has been reported as a feasible and safe procedure ...
متن کاملEndovascular repair of latrogenic subclavian artery perforations using the Hemobahn stent-graft.
PURPOSE To report the use of a new self-expanding endograft for percutaneous treatment of iatrogenic subclavian artery perforations. CASE REPORTS The subclavian artery of 2 patients was inadvertently cannulated during percutaneous attempts to implant a permanent pacemaker in one and catheterize the subclavian vein in the other. Because both patients had serious comorbidities, endovascular rep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Vascular Medicine & Surgery
سال: 2014
ISSN: 2329-6925
DOI: 10.4172/2329-6925.1000128