Steady state vibration tests of a six-storey reinforced concrete building
نویسندگان
چکیده
منابع مشابه
Dynamic testing of a four-storey building with reinforced concrete and unreinforced masonry walls: prediction, test results and data set
This paper presents the results of a series of shake-table tests on a half-scale, four-storey building with reinforced concrete and unreinforced masonry walls. Due to the lack of reference tests, the seismic behaviour of such mixed structures is poorly understood. The test unit was subjected to several runs of increasing intensity yielding performance states between minor damage and near collap...
متن کاملA Study of Dynamic Characteristics of a Multistory Building Using Ambient Vibration Tests (TECHNICAL NOTE)
Dynamic characteristics of a typical multistory building in Iran have been studied in two different stages of building construction, using ambient vibration tests. Finite element models have also been used to determine these characteristics and to verify test results. The results indicated the agreements and also differences between conventional theoretical models and the behaviour of real stru...
متن کاملCritical Points of Prefabricated Reinforced Concrete Wall Systems of Multi-storey Buildings
With respect to the dissipation of energy through plastic deformation of joints of prefabricated wall units, the paper points out the principal importance of efficient reinforcement of the prefabricated system at its joints. The method, quality and amount of reinforcement are essential for reaching the necessary degree of joint ductility. The paper presents partial results of experimental resea...
متن کاملTapered Polymer Fiber Sensors for Reinforced Concrete Beam Vibration Detection
In this study, tapered polymer fiber sensors (TPFSs) have been employed to detect the vibration of a reinforced concrete beam (RC beam). The sensing principle was based on transmission modes theory. The natural frequency of an RC beam was theoretically analyzed. Experiments were carried out with sensors mounted on the surface or embedded in the RC beam. Vibration detection results agreed well w...
متن کاملSeismic Damage Analysis of Reinforced Concrete Building Considering Member Fracture
The Adaptively Shifted Integration (ASI) technique, which produces the highest computational efficiency in the finite element analyses of framed structures including static and dynamic collapse problems, is applied to the seismic damage analysis of a reinforced concrete building. By expressing member fracture by a plastic hinge located at the exact position with a simultaneous release of result...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of the New Zealand Society for Earthquake Engineering
سال: 1971
ISSN: 2324-1543,1174-9857
DOI: 10.5459/bnzsee.4.1.94-107