Statistical analysis of audible noise generated by AC corona discharge from single corona sources

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Confirmed assignments of isomeric dimethylbenzyl radicals generated by corona discharge.

The controversial vibronic assignments of isomeric dimethylbenzyl radicals were clearly resolved by using different precursors. By employing corresponding dimethylbenzyl chlorides as precursors, we identified the origins of the vibronic bands of the dimethylbenzyl radicals generated by corona discharge of 1,2,4-trimethylbenzene. From the analysis of the spectra observed from the dimethylbenzyl ...

متن کامل

Conductor Corona Noise Prediction on High Voltage Ac Lines

The conductor corona noise of four local 400 kV AC transmission lines is measured and compared to predictions. The prediction software developed is based on the EPRI semi-analytical approach using excitation functions and the theory of natural modes. The nature and accuracy of the prediction software is discussed along with relevant corona noise metrology issues encountered.

متن کامل

Assessment of the Long-Term Levels for Corona Audible Noise in Vicinity of UHV Transmission Lines

In the paper characteristic features of the corona noise from UHV transmission lines have been distinguished, which can be useful for the noise measurement under high level interference conditions. The utility of statistical methods in elimination of typical environmental interference has been shown, particularly methods based on the measurement of statistical spectra. The effect of inaccurate ...

متن کامل

Control of separated flows with the ionic wind generated by a DC corona discharge

This paper describes the investigation of a DC surface corona discharge established on a rounded edge of a dielectric material. The ionic wind induced by the discharge was measured with the Particle Image Velocimetry system. A physical induced flow model is proposed to interpret the shape of the velocity field. Experiments on a flat plate and a NACA 0015 were performed in a subsonic wind tunnel...

متن کامل

Decontamination effects of low-temperature plasma generated by corona discharge. Part I: an overview.

The first part of this article is devoted to a minireview of basic terms of plasma physics and chemistry described in a way understandable even to nonspecialists in the field. Among the methods of generation of low-temperature plasma, the unipolar electric corona discharge in air at atmospheric pressure is described in more detail. Selected studies are mentioned that concern the decontamination...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: High Voltage

سال: 2018

ISSN: 2397-7264,2397-7264

DOI: 10.1049/hve.2017.0159