Static pressure correction in high Reynolds number fully developed turbulent pipe flow
نویسندگان
چکیده
منابع مشابه
Static pressure correction in high Reynolds number fully developed turbulent pipe flow
Measurements are reported of the error in wall static pressure reading due to the finite size of the pressure tapping. The experiments were performed in incompressible turbulent pipe flow over a wide range of Reynolds numbers, and the results indicate that the correction term (as a fraction of the wall stress) continues to increase as the hole Reynolds number d+ = uτd/ν increases, contrary to p...
متن کاملPitot probe corrections in fully developed turbulent pipe flow
Mean flow measurements taken in fully developed turbulent pipe flow over a wide Reynolds number range are used to evaluate current methods of correcting Pitot probe data. Based on this evaluation, a new form for the displacement correction is proposed which appears to be more accurate over a wider range of conditions than those currently available. The difficulty of obtaining the true near-wall...
متن کاملStructure and dynamics of low Reynolds number turbulent pipe flow.
Using large-scale numerical calculations, we explore the proper orthogonal decomposition of low Reynolds number turbulent pipe flow, using both the translational invariant (Fourier) method and the method of snapshots. Each method has benefits and drawbacks, making the 'best' choice dependent on the purpose of the analysis. Owing to its construction, the Fourier method includes all the flow fiel...
متن کاملTurbulent pipe flow at extreme Reynolds numbers.
Both the inherent intractability and complex beauty of turbulence reside in its large range of physical and temporal scales. This range of scales is captured by the Reynolds number, which in nature and in many engineering applications can be as large as 10(5)-10(6). Here, we report turbulence measurements over an unprecedented range of Reynolds numbers using a unique combination of a high-press...
متن کاملPIV Measurements of turbulence statistics and near-wall structure of fully developed pipe flow at high Reynolds number
Fully developed turbulent pipe flow at Re=11300 as well as Re=5300 is measured by PIV using water as working fluid. Excellent agreement with DNS (Direct Numerical Simulation) by Satake (2000) is achieved by choosing optimum measurement parameters such as spatial resolution, time separation of two images, and number of samples. The test section is 6.7m long stainless steel pipe with transparent ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Measurement Science and Technology
سال: 2002
ISSN: 0957-0233
DOI: 10.1088/0957-0233/13/10/314