STATCOM and Capacitor Banks in a Fixed-speed Wind Farm
نویسندگان
چکیده
منابع مشابه
Unbalanced Grid Faults Ride By StatCom Control at Fixed Speed Induction Generator Wind Farm
Fixed speed induction generator (FSIG) having high asymmetrical fault percentage than variable speed. Even though there are different ways to control these faults StatCom control method to compensate reactive power is one of the useful and highly beneficial method. In this paper the FSIG wind farm is observed under unbalanced grid fault with StatCom connected to it with the help of MATLAB simul...
متن کاملStabilization of a Fixed Speed IG Based Wind Farm using Variable Speed PMSG
To optimize the output power and reduce the frequency fluctuation in conventional fixed speed Induction Generator (IG) based wind farm, various controlling devices are used. But, this paper proposes that Permanent Magnet Synchronous Generator (PMSG) can work both as a power producing device and as a controlling device for IG. In this paper a more practical case has been considered where a wind ...
متن کاملA Novel Strategy for Wind Speed Prediction in Wind Farm
The empirical mode decomposition (EMD) is well known for predicting wind speed.However, but the joint application of relevance vector machine (RVM) and empirical mode decomposition in wind speed forecasting is seldom found in the field. This paper proposes a relevance vector machine model based on empirical mode decomposition to predict the wind speed. Before the wind speed forecasting with RVM...
متن کاملDynamic characterization and predictability analysis of wind speed and wind power time series in Spain wind farm
The renewable energy resources such as wind power have recently attracted more researchers’ attention. It is mainly due to the aggressive energy consumption, high pollution and cost of fossil fuels. In this era, the future fluctuations of these time series should be predicted to increase the reliability of the power network. In this paper, the dynamic characteristics and short-term predictabili...
متن کاملSimulation and Study of Power Quality Issues in a Fixed Speed Wind Farm Substation
Power quality issues associated with the fixed speed wind farm substation located at Coimbatore district are investigated as the wind generators are tripping frequently. The investigations are carried out using two power quality analyzers, Fluke 435 and Dranetz PX5.8, with one of them connected at group control breaker of the 110 kV feeder and the other at the selected 0.69 kV generator busbar ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energy Procedia
سال: 2014
ISSN: 1876-6102