Standardless semi-quantitative analysis by PIXE
نویسندگان
چکیده
منابع مشابه
Semi-Quantitative Comparative Analysis
Comparative analysis (CA) of dynamical systems is an important problem in qualitative reasoning. CA techniques predict differences in the behavior of two systems as a consequence of differences in the initial conditions or structural differences. A disadvantage of these techniques is the imprecision of the possible answers due to their qualitative nature. This report presents SQCA, an implement...
متن کاملProgress towards Accurate Quantitative Standardless X-ray Analysis at Low kV
At 20kV, quantitative analysis with relative errors below 5% can be delivered by EDS standardless analysis provided SDD detector efficiency is accurately determined and standards have been pre-measured on a well-characterised detector [1]. The increasing need to analyse features well below 1 μm in size has encouraged use of lower beam voltages. At 5 kV, there is at least one accessible line emi...
متن کاملAnalysis of Submandibular Salivary Calculus by External PIXE
This work presents the study by external PIXE of two giant submandibular obtained from different individuals. The backscattered protons were detected to perform Rutherford Backscattering Spectrometry (RBS) simultaneously to PIXE. These calculi are rare and presented a layered structure; an elemental profile was obtained: P, Ca, O are commonly detected; Cl, Fe, Cu, Zn, Br and Sr are detected in ...
متن کاملExpression pattern analysis of TomPRO2 and LaPA1 genes in tomato under in vitro salt stress by Semi-quantitative RT-PCR
The expression pattern of TomPRO2 and LaPA1 genes in two tomato (Lycopersicon esculentum) cultivars named as Isfahani and Shirazi under in vitro salt stress were investigated. Four to six weeks old in vitro grown seedlings were transferred on MS medium containing 0, 80 and 160 mM NaCl and untreated plants were used as control. RNA was extracted from root and leaf and then cDNA was synthesized. ...
متن کاملThe concentration of heavy trace elements in pigment and cholesterol humangallstones: Comparative studies by PIXE analysis.
Background: The method of proton induced X-ray emission (PIXE) has been widely used as a sensitive technique to trace elemental analysis in both biological and medical fields. The sensitivity of this powerful method is in the order of ppm .The aim of this work is to analyze structural composition of 4 heavy trace elements with Z greater than 24 (Mn, Fe, Cu, Zn) in two kinds of gallstones and to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Analytical Atomic Spectrometry
سال: 2017
ISSN: 0267-9477,1364-5544
DOI: 10.1039/c7ja00068e