Standardization of Creatine Kinase-MB (CK-MB) Mass Assays: The Use of Recombinant CK-MB as a Reference Material
نویسندگان
چکیده
منابع مشابه
Standardization of creatine kinase-MB (CK-MB) mass assays: the use of recombinant CK-MB as a reference material.
BACKGROUND The AACC assembled a committee to identify and validate a standard creatine kinase MB isoenzyme (CK-MB) material to improve the comparability of CK-MB mass assays. METHODS Three protocols were used. In protocol I, various CK-MB materials prepared in different matrices were screened as candidate standards. In protocol II, participating manufacturers calibrated their systems with con...
متن کاملEffects of hemolysis on the assays of serum CK, CK-MB activities and CK-MB (mass), troponin and myoglobin measurements
Aim: The aim of the study was to investigate the effects of in vitro hemolysis on serum creatine kinase and creatine kinase MB isoenzyme activities with creatine kinase MB mass, troponin I and myoglobin measurements. Materials and methods: We prepared serum pools having analyte concentrations at normal and pathological values. Hemolysate was added into serum pools to obtain aliquotes with final...
متن کاملDiagnostic application of CK-MB mass determination.
Recent advances in analytic techniques have increased the diagnostic value of creatine kinase MB (CK-MB), enabling earlier and more sensitive results. The CK-MB mass immunoassays, that utilise the monoclonal anti-CK-MB in conjunction with anti-M or anti-B antibodies, are able to measure accurately small changes during the early hours after myocardial infarction (MI). CK-MB has two main limitati...
متن کاملMacro-creatine kinase co-migrating with CK-MB on electrophoresis.
Certain types ofmacro-CK, type 1, have been reported to cause false increases in CK-MB by co-migration on electrophoresis (1-3). I report two such cases in which the macroCK was an IgA with anti-CK-BB specificity. According to methods proposed by Medeiros et al. (1), immunoprecipitation and subsequent analysis by elecrophoresis was used to separate interfering macre-CK from CK-MB. CK electropho...
متن کاملProficiency testing for creatine kinase isoenzyme CK-2 (CK-MB) in Ontario.
Three surveys of the measurement and interpretation of creatine kinase (CK; EC 2.7.3.2) isoenzyme 2 (CK-MB) were conducted in Ontario, Canada, in 1989. Of the clinical laboratories participating, 66% used immunological methods and 24% used electrophoretic methods. Although reference ranges and interpretative routines varied widely, 95% of the laboratories reported correct interpretations for 10...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1999
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/45.9.1414