Standardization of C-Peptide Measurements

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standardization of C-peptide measurements.

BACKGROUND C-peptide is a marker of insulin secretion in diabetic patients. We assessed within- and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results. METHODS We sent 40 different serum samples to 15 laboratories, which used 9 different routine C-peptide assay metho...

متن کامل

International comparison of C-peptide measurements.

BACKGROUND C-peptide measurement has been widely used as a marker of insulin secretion in patients with diabetes. We assessed the comparability of C-peptide results obtained with different methods and by different laboratories and determined whether C-peptide results could be harmonized by normalization with a WHO reference reagent or with plasma. METHODS We sent 16 different heparin plasma s...

متن کامل

Nontransferability of C-peptide measurements with various commercial radioimmunoassay reagents.

I evaluated the between-method variation of C-peptide determined with C-peptide radioimmunoassay kit reagents from Mallinckrodt, Behring, Diagnostic Products Corp., and Immuno Nuclear Corp., and antisera from Novo (M1230, M1221, and K6) and Cambridge Medical Diagnostics (299-029P). C-peptide concentrations corresponding to 0.6 nmol/L (as determined with M1230) ranged from 0.54 (by Immuno Nuclea...

متن کامل

Interlaboratory standardization of measurements of glycohemoglobins.

The diversity of methods used to measure glycohemoglobins (GHb) makes it difficult to compare patients' results among laboratories. We reported previously the feasibility of providing comparable results from different assays by use of common calibrators. We here compare results from seven different GHb methods calibrated by use of hemolysates assayed by a precise ion-exchange high-performance l...

متن کامل

Moving Toward Standardization of Urine Albumin Measurements

Measurement of urine albumin is important for detecting and monitoring kidney disease. At the present time, measurement of urine albumin is not standardized due to the lack of a reference system, which includes both a reference measurement procedure and certified reference materials. Developing a reference system will provide a means for clinical laboratory measurement procedures to become stan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Clinical Chemistry

سال: 2008

ISSN: 0009-9147,1530-8561

DOI: 10.1373/clinchem.2007.101287