Staging of laryngeal cancer using 64-channel multidetector row CT: comparison of standard neck CT with dedicated breath-maneuver laryngeal CT.

BACKGROUND AND PURPOSE With a 64-channel multidetector row CT, imaging acquisition during speech, swallowing, or phonation has become feasible. However, the actual benefit of these additional focused images should be critically evaluated with respect to radiation dose. The purpose of this study was to determine if dedicated laryngeal CT using breath-holding and straw-blowing improved the accura...

متن کامل

CT findings of laryngeal tuberculosis: comparison to laryngeal carcinoma.

PURPOSE Our goal was to describe the appearance of laryngeal tuberculosis using CT, with the intent of identifying features distinguishing laryngeal tuberculosis and carcinoma. METHOD CT scans of 12 patients with laryngeal tuberculosis were analyzed retrospectively. Clinical symptoms, laryngoscopic exams, and presence of pulmonary tuberculosis on chest radiographs were also reviewed. RESULT...

متن کامل

Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.

BACKGROUND AND PURPOSE Recently introduced 320-detector row CT enables whole brain perfusion imaging compared to a limited scanning area in 64-detector row CT. Our aim was to evaluate patient radiation exposure in comprehensive stroke imaging by using multidetector row CT consisting of standard CT of the head, CTA of cerebral and cervical vessels, and CTP. MATERIAL AND METHODS Organ doses wer...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

[Overview of cardiac contrast examination using 64-row multislice CT].

ECG-gated multislice CT(MSCT)now supports not only morphological but also functional diagnosis. In order to improve accuracy in the functional analysis of cardiac motion, it is important to depict the endocardial and epicardial contours. The present study was conducted to evaluate a method in which contrast medium and physiological saline solution(saline)are injected simultaneously, and the iod...