Stable Oxygen and Deuterium Isotope Techniques to Identify Plant Water Sources
نویسندگان
چکیده
منابع مشابه
Simultaneous monitoring of stable oxygen isotope composition
Introduction Conclusions References
متن کاملStable Oxygen and Hydrogen Isotope Fractionation Factors for the Goethite (hematite)-water System
This paper reports experimental results on the low-temperature (<100 oC) 18O and 2H fractionation of goethite (hematite)-water in a closed system. Both goethite (-FeOOH) and hematite (-Fe2O3) exhibited closer fractionation factor values but the Hematite-Water value is slightly higher (~0.9932) than the Goethite-Water (~0.9924) for the 18O isotope. The average fractionation factor (1000ln...
متن کاملA new value for the stable oxygen isotope fractionation between dissolved sulfate ion and water
Although the stable oxygen isotope fractionation between dissolved sulfate ion ðSO 4 Þ and H2O (hereafter aðSO2 4 –H2OÞ) is of physico-chemical and biogeochemical significance, no experimental value has been established until present. The primary reason being that uncatalyzed oxygen exchange between SO 4 and H2O is extremely slow, taking 10 5 years at room temperature. For lack of a better appr...
متن کاملHydration in solution is critical for stable oxygen isotope fractionation between carbonate ion and water
Various isotope studies require accurate fractionation factors (a’s) between different chemical compounds in thermodynamic equilibrium. Although numerous isotope systems involve aqueous solutions, the conventional theory is formulated for the gas-phase and predicts incorrect a’s for many compounds dissolved in water. Here I show that quantum-chemistry calculations, which take into account solut...
متن کاملSpectral analysis software improves confidence in plant and soil water stable isotope analyses performed by isotope ratio infrared spectroscopy (IRIS).
Previous studies have demonstrated the potential for large errors to occur when analyzing waters containing organic contaminants using isotope ratio infrared spectroscopy (IRIS). In an attempt to address this problem, IRIS manufacturers now provide post-processing spectral analysis software capable of identifying samples with the types of spectral interference that compromises their stable isot...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Water Resource and Protection
سال: 2014
ISSN: 1945-3094,1945-3108
DOI: 10.4236/jwarp.2014.615137