Stability Tests on Anion Exchange Membrane Water Electrolyzer under On-Off Cycling with Continuous Solution Feeding
نویسندگان
چکیده
In this study, the stability of an anion exchange membrane water electrolyzer (AEMWE) cell was evaluated in on-off cycling operation with respect to applied electric bias, i.e., a current density 500 mA cm−2, and open circuit. The ohmic polarization resistances system were monitored during (~800 h) using electrochemical impedance spectra. Specific consideration given resistance cell, especially that under conditions, by consistently feeding KOH solution. Owing excess feed solution, momentary increase observed immediately after open-circuit. solution mostly recovered subjecting bias. Stability tests on AEMWE continuous even circuit can guarantee long-term avoiding irreversible resistances.
منابع مشابه
Real-Time Microscopic Monitoring of Flow, Voltage and Current in the Proton Exchange Membrane Water Electrolyzer
Looking for alternative energy sources has been an inevitable trend since the oil crisis, and close attentioned has been paid to hydrogen energy. The proton exchange membrane (PEM) water electrolyzer is characterized by high energy efficiency, high yield, simple system and low operating temperature. The electrolyzer generates hydrogen from water free of any carbon sources (provided the electron...
متن کاملX-ray Lithography on Perovskite Nanocrystals Films: From Patterning with Anion-Exchange Reactions to Enhanced Stability in Air and Water
Films of colloidal CsPbX3 (X = I, Br or Cl) nanocrystals, prepared by solution drop-casting or spin-coating on a silicon substrate, were exposed to a low flux of X-rays from an X-ray photoelectron spectrometer source, causing intermolecular C═C bonding of the organic ligands that coat the surface of the nanocrystals. This transformation of the ligand shell resulted in a greater stability of the...
متن کاملthe washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests
در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است
15 صفحه اولon some bayesian statistical models in actuarial science with emphasis on claim count
چکیده ندارد.
15 صفحه اولAnion Exchangers for Water Treatment: Ion Exchange
ation sciences is the puriRcation and recovery of solvents especially from HPLC and GPC usage. There is a range of equipment supplied for recycling of solvents and useful sources of information can be found on the internet, for example the web pages for B/R Instruments and Recycling Sciences are included in the Further Reading. The applications of distillation in analysis are widespread, with t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of electrochemical science and technology
سال: 2022
ISSN: ['2093-8551', '2288-9221']
DOI: https://doi.org/10.33961/jecst.2022.00241